The XHGG502A ARC Cable Fault Pre-Locator is engineered for the reality of field operations — dust, moisture, temperature extremes, and the pressure to diagnose faults quickly with minimal downtime. Built into an IP54-rated protective chassis and powered by an 11.1V lithium battery pack with 2-hour fast charging that delivers over 5 hours of continuous operation, it combines 0.07m ultra-high-resolution fault pre-location with the ruggedness required for substations, cable trenches, and outdoor test environments where instruments are subjected to the elements daily.
At its core, the XHGG502A deploys an 8-pulse (multiple-pulse) ARC method through a DC 35kV pulse coupler, converting complex high-resistance fault waveforms into easily interpretable short-circuit equivalent traces. An embedded system with a 10.1-inch sunlight-readable TFT touch display (280nit, 1024×600) provides dual-mode operation — touchscreen for software navigation and coded push-buttons for gloved-hand control in wet or dirty conditions. The instrument also supports conventional low-voltage pulse (300V, 8 selectable widths) and high-voltage flashover methods, covering the complete fault spectrum from zero-ohm shorts to flashover high-impedance failures.
![]()
| XHGG502A — IP54 Rugged Platform | |
|---|---|
| Sampling Frequency | 1MHz~400MHz |
| Minimum Resolution | 0.07m |
| Test Range | ≥120km (10 presets: 100m~100km) |
| Test Blind Zone | ≤10m |
| Measurement Error | ≤±(0.5%×L+1m) |
| Low Voltage Pulse | 300V±15%; 8 widths: 0.1/0.30/0.60/1.20/2.4/5.0/7.5/10μs |
| Pulse Coupler | DC 35kV; 430×380×220mm; 10kg |
| Test Methods | LV pulse (TDR), HV flashover, 8-pulse ARC (multi-pulse) |
| Display | 10.1-inch TFT touch; 1024×600; 280nit |
| Platform | Embedded system; touch + coded button dual operation |
| Waveform Storage | 8,000+ LV/HV records; 250+ multi-pulse records; USB export |
| Battery | Built-in 11.1V lithium; ~2hr charge; 5hr+ operation |
| Power Input | AC 110V~240V, 50Hz/60Hz |
| Protection | IP54 rugged protective chassis |
| Host Dimensions | 358×284×168mm |
| Host Weight | 5kg |
| Operating Conditions | -20℃~+65℃; ≤90% RH; 750±30mmHg |
| Compliance | GB/T 18268.1; DL/T 849.1-2019; JJF1042-2020; CE; ISO |
| Test Method | Fault Types Detected | Typical Application |
|---|---|---|
| LV Pulse (TDR) | Low-resistance, short-circuit, open-circuit, disconnection | Daily cable network maintenance, pre-splice verification |
| HV Flashover | High-resistance leakage (above several hundred Ω); flashover faults | Post-withstand-test diagnosis, aging cable assessment |
| 8-Pulse ARC | All high-resistance faults — converts to short-circuit equivalent waveform | Complex faults with ambiguous single-pulse signatures; difficult-to-interpret traces |
The XHGG502A's embedded software includes reference waveform templates for the most common cable fault scenarios, enabling operators to compare field traces against known signatures for rapid identification:
12-month free warranty against product quality defects from date of purchase. Lifetime maintenance and technical support services. Each XHGG502A ships complete with: pre-locator host, DC 35kV pulse coupler, test lead set, AC power adapter/charger, USB communication cable, rugged transport cases (host + coupler), user manual, and warranty certificate.
Q: What is ARC multi-pulse technology and how does it compare to traditional HV flashover?
ARC (Arc Reflection Comparison) multi-pulse technology extends the arc duration at the fault point and captures 8 waveform groups simultaneously, providing a clean short-circuit-like echo for unambiguous distance measurement. Unlike traditional HV flashover which produces complex cosine-oscillation waveforms that require expert interpretation, ARC multi-pulse delivers clear, easy-to-analyze results even for complex high-resistance and flashover faults.
Q: What types of cables and faults can the XHGG502A detect?
The XHGG502A handles power cables rated 35kV and below across all common insulation types: XLPE, oil-impregnated paper, and rubber/plastic dielectric. It detects open-circuit, short-circuit, low-resistance (via LV pulse method), high-resistance leakage, and flashover faults (via HV flashover and ARC multi-pulse methods). It also supports cable length measurement and wave velocity calibration for coaxial, street light, and buried cables of various cross-sections.
Q: Can the XHGG502A be used outdoors in bright sunlight?
Yes. The 10.1-inch full-color TFT display delivers 280-nit brightness at 1024x600 resolution, ensuring clear waveform visibility even under direct sunlight. The IP54-rated rugged chassis protects against dust ingress and water splashes, making the XHGG502A fully suitable for outdoor field operations in challenging environments.
Q: How long does the battery last and how fast does it charge?
The built-in 11.1V high-capacity lithium battery provides 5+ hours of continuous operation on a full charge. Fast charging technology achieves a full charge in approximately 2 hours. The tester also supports AC 110V~240V direct power operation, so you can charge and test simultaneously when mains power is available.
Q: Can I export waveforms for reporting and analysis?
Yes. The XHGG502A stores 8000+ low-voltage and high-voltage waveform records and 250+ multi-pulse records onboard with Chinese-character naming. Via USB connection and the included PC waveform management software, you can export files for archival analysis, generate client reports, and print waveform images. The software also supports waveform comparison across maintenance cycles.
Q: What does IP54 protection mean for daily field use?
IP54 means the XHGG502A chassis is dust-protected (limited dust ingress that does not interfere with operation) and splash-proof against water from any direction. This rugged design allows the tester to be used in dusty construction sites, light rain conditions, and humid underground cable vaults without risk of internal damage. Combined with the -20°C to +65°C operating temperature range, it is purpose-built for demanding field environments.
Contact us for pricing, on-site demonstration, or technical consultation on the XHGG502A Rugged ARC Cable Fault Pre-Locator.
Overall Rating