logo
Send Message
Home > products >
AC DC Hipot Tester
>
Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized

Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: CE, ISO
Model Number: XHZG series
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE, ISO
Model Number:
XHZG series
Model NO.:
XHZG Series
Power:
Electricity
Customized:
Customized
Color:
Black
Output Power (W):
Output Voltage*Output Current
Charging Current (Ma):
Output Current (Ma)
Transport Package:
Wooden Box With Foam Inside
Trademark:
XZH TEST
Supply Ability:
1000
Warranty:
1 Year
Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
5-8 days
Payment Terms:
T/T
Supply Ability:
1000 PCS/Year
Product Description

 

 

Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized

 

Product Description


 

The DC high voltage tester is mainly used in the power departments of electric power, mining, metallurgy, steel and other enterprises to perform DC withstand voltage test or DC leakage current test on high voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, circuit breakers, generators, etc.

 

Detailed Photos

Xzh Test 60-300kv Customizable Cable Transformer DC High Voltage Generator
Product Parameters

 

                     Specification
 
Technical Parameters
60/2 60/3 80/10 120/2 120/3
The output voltage (kV) 60 60 80 120 120
Output current (mA) 2 3 10 2 3
Output Power (W) 120 180 800 240 360
recharging current (mA) 2 3 10 2 3
Control box weight(kg) 2 2 2 2 2
Weight of spare cylinder(kg) 2.5 2.5 4 4 4
Specifications of spare cylinder(mm) Ф90
340
Ф90
340
Ф90
470
Ф90
470
Ф90
470
Voltage measurement error 1% (full scale) ±1 character
Current measurement error 1% (full scale) ±1 character
Overvoltage setting error Overvoltage protection is set by dial, which is clear at a glance (accuracy ≤ 1.0%)
0.75Switching error High-precision 0.75UDC-1mA single-touch button (accuracy ≤1.0%)
Best suited for zinc oxide arrester testing
Ripple Factor ≤0.5%
Way of working Intermittent use: rated load 30 minutes
1.1 times rated voltage use: 10 minutes
working environment Temperature: -10°C~+40°C
Relative humidity: not more than 85% at room temperature of 25ºC (no condensation)
Altitude: below 1500 meters
With capacitive load No limit on the capacitance of the test product
Structural features Electrical insulation voltage doubler
Air insulation, no leakage concerns

Xzh Test 60-300kv Customizable Cable Transformer DC High Voltage Generator
Operation panel instructions

 

1. Digital ammeter: Digitally displays DC high voltage output current.
2. Digital voltmeter: Digitally displays DC high voltage output voltage.
3. Yellow lighted button: Valid when the red light is on. When the yellow button is pressed, the yellow light is on, and the output high voltage drops to 0.75 times the original value, and this state is maintained for one minute. This function is specially used for zinc oxide lightning arresters to quickly measure 0.75UDC-1mA. Press the green button, the red and yellow lights are off, the high voltage is cut off and exits the 0.75 times state.
4. Red lighted button: High voltage connection button, high voltage indicator light. When the green light is on, press the red button, the red light is on and the green light is off, indicating that the high voltage circuit is connected, and the voltage can be increased at this time. This button is only valid when the voltage adjustment potentiometer returns to zero. If the red light is on and the green light is still on when the red button is pressed, but the red light goes out and the green light comes on when the button is released, it means that the protection circuit in the machine has worked. At this time, you must turn off the machine to check whether the overvoltage setting dial switch setting is less than 5% of the full scale and whether there are other faults before turning it on.
5. Green lighted button: The green light indicates that the power is on and the high voltage is disconnected. When the red light is on, press the green button, the red light goes out and the green light comes on, and the high voltage circuit is cut off.
6. Power switch: Press this switch to the right, the power is on, and the green light comes on. Otherwise, it is off.
7. Overvoltage setting dial switch: used to set the overvoltage protection value. The overvoltage setting range is 0.05 to 1.2 times the rated voltage, and the value displayed by the dial switch is in kV.
8. Voltage adjustment potentiometer: This potentiometer is a multi-turn potentiometer. Clockwise rotation is for voltage increase, and reverse rotation is for voltage reduction. This potentiometer has an electronic zero position protection function, so it must be returned to zero before voltage increase.
9. Power input socket: Connect the power cord provided with the machine to the power input socket. (AC 220V ±10%, with built-in fuse in the socket.)
10. Grounding terminal: This grounding terminal is connected to the grounding terminal of the voltage multiplier and the grounding of the test piece at one point and then connected to the grounding grid.
11. Intermediate frequency and measurement cable quick connection socket: used to connect the chassis to the voltage multiplier. When connecting, just align the cable plug with the socket and push it into place. When removing the wire, first move the outer clamp of the cable plug backwards and apply a little force.

 

 

Technical Parameters

 

Xzh Test 60-300kv Customizable Cable Transformer DC High Voltage Generator
Xzh Test 60-300kv Customizable Cable Transformer DC High Voltage Generator


Features
1. The chassis adopts international universal chassis, which can be used vertically or horizontally.
2. It adopts medium frequency voltage doubler circuit, applies PWM pulse width modulation technology and high-power IGBT devices.
3. It adopts large voltage feedback, with high output voltage stability and small ripple coefficient ≤1%.
4. Full range smooth voltage regulation, good voltage regulation fineness, regulation accuracy ≤0.5%, stability ≤1%, voltage and current error 1%±1 word.
5. Boost potentiometer starts from zero to boost.
6. 0.75UDC1mA function button, convenient for zinc oxide lightning arrester test, accuracy ≤1%.
7. Overvoltage protection adopts code setting, which is clear at a glance, and the error is ±1%.

Packaging & Shipping

 

 

Xzh Test 60-300kv Customizable Cable Transformer DC High Voltage Generator

 


 

Company profile

 

 

XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.

 

Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.

 

What we can do

 

We have the ability to innovate new products and technologies.

 

We can provide complete system solutions for your project.

 

We provide online and offline practical and theoretical training.

 

We provide instrument repair and calibration.

 

Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 5Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 6Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 7Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 8Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 9Xzh Test 60-300kv Customized Cable Transformer High Voltage Generator Customized 10

 


 

 

FAQ

1. Are you a trading company or a manufacturer?

We are a professional manufacturer with more than 10 years of experience. We can strictly control the quality of parts and finished products.

 

2. What is the delivery time and inventory?

If our best-selling products are in stock, it will be 5-8 working days for shipment. But for mass production and customized production, the time will take 2-4 weeks.

 

3. What are your payment terms?

Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can be negotiated.

 

4. How long is your product warranty?

We provide 1 year warranty for the equipment.

 

5. How do you ensure quality?

The product links include R&D, manufacturing, commissioning and technical support, following strict and scientific management principles. Therefore, we can support strong production and R&D capabilities, and can produce high-quality products at competitive prices to meet customers' high requirements.

 

6. What support can I get?

We will provide training support, marketing support, technical support and supply chain support. You can contact us for more information.

 

7. Where is your factory? Can I visit your factory?

We are located in Xi'an, Shaanxi, China. We are close to Xi'an Xianyang International Airport, which is about 2 and half hours by plane from Shanghai and Guangzhou. All customers from all over the world are welcome to visit us.

 

8. How to become your dealer?

Every company interested in power system instruments can contact us without hesitation, including website letters, emails, telephones, etc. We will contact you quickly according to your company information and cooperation intentions.