The XHHV535-2L is an ultra-light portable DC high-voltage surge generator delivering 1225J discharge energy at up to 35kV for underground power cable fault location and DC withstand testing. At just 25kg, it is the lightest unit in the XHHV535 series—making it the ideal choice for field engineers who prioritize maximum portability without sacrificing capability.
Integrating a DC high-voltage source, 2μF energy storage capacitor, and high-voltage discharge ball gap into a single compact chassis, the XHHV535-2L completely replaces traditional test transformers, operation boxes, and pulse energy storage capacitors weighing over 100 kilograms combined. Its short-circuit-proof output design allows the high-voltage output to directly short-circuit to ground while continuing normal operation—truly indestructible by impulse. Fully compliant with DL/T846-2016 and DL/T474-2017.
| Impact High Voltage | 0~35kV (default 0~32kV) |
|---|---|
| Burn-Through Voltage | 0~32kV |
| Built-in Capacitor | 2μF |
| Discharge Energy | 0~1225J (default 0~1024J) |
| Output Voltage Polarity | Negative polarity |
| Short Circuit Current | 0~320mA |
| Impact Power | 400W |
| High Voltage Accuracy | 1.5 level |
| Over-Temperature Protection | 65°C |
| Overcurrent Protection | 8mA (>4S) high voltage side |
| Weight | No more than 25kg |
| Dimensions | 540L x 310W x 460H mm |
| Power Supply | AC220V±10%, 50Hz±1Hz (60Hz customizable) |
| Ambient Temperature | -25 ~ +65°C |
| Component | Qty | Description |
|---|---|---|
| Host Unit | 1 | Integrated DC high-voltage surge generator |
| High Voltage Output Cable | 1 | Connects host to cable core under test |
| Ground Wire | 1 | 4mm² instrument ground + 2.5mm² discharge rod ground |
| Power Cable | 1 | AC220V instrument power cord |
| Fuse | 5 | Backup fuses for AC220V power system |
| Discharge Rod | 1 | DC current-limiting / short-circuit discharge |
The XHHV535-2L is purpose-built for field service technicians, independent cable testing contractors, and utility maintenance crews who need a one-person-portable surge generator that can be carried between sites without lifting equipment. At just 25kg, it suits single-operator transport to confined vaults, manholes, and remote substations. Ideal for low-voltage distribution cable fault location, commissioning testing of new cable installations, and scheduled preventive maintenance programs where rapid deployment and minimal logistical footprint are critical.
Q: How does a high voltage surge generator work in cable fault detection?
The surge generator discharges a high-energy pulse into the faulty cable, creating a controlled high-voltage arc at the fault point. This arc produces both an acoustic signal (loud thumping sound detectable by ground microphones) and an electromagnetic pulse (detectable by an inductive receiver). By combining acoustic and electromagnetic signal arrival times, operators can pinpoint the exact fault location with precision—a technique known as acoustic-magnetic synchronization.
Q: Which voltage range should I select for different cable types?
Voltage selection follows the cable's rated operating voltage as a general guideline. For low-voltage cables (up to 1kV), use the 8kV or 12kV range. For medium-voltage distribution cables (6-15kV), the 16kV range is appropriate. For high-voltage transmission cables (35kV and above), use the 32kV range. Always consult the cable manufacturer's maximum test voltage specifications and ensure all safety clearances are maintained during high-voltage operation.
Q: What safety precautions must be observed during surge generator operation?
High voltage surge generator testing requires strict safety protocols. Always verify the cable is fully de-energized and isolated from all power sources before connection. Establish a minimum 5-meter safety perimeter around the test zone with warning signs. All personnel must wear appropriate PPE including arc-rated clothing, HV insulating gloves, and dielectric overshoes. The integrated safety features—automatic discharge upon power-off, emergency stop, and zero-voltage interlock—provide additional layers of protection but should never replace proper safety procedures.
Q: What is the advantage of multiple energy levels (Joules) on this unit?
Different energy levels serve different diagnostic purposes. Low energy settings (e.g., 864J–1024J) are ideal for initial fault confirmation and locating high-resistance faults where excessive energy could worsen cable damage. Medium energy (1225J–2048J) provides optimal acoustic signal strength for most routine fault pinpointing. High energy (2450J+) is reserved for very long cables, deep burial scenarios, or high-impedance faults that require stronger arc generation to produce a detectable acoustic signature. The three-level selection allows operators to match energy output to field conditions.
Q: What warranty and support is included with this surge generator?
12-month standard warranty against manufacturing defects with lifetime technical support. CE and ISO 9001:2015 certified. Each unit includes the surge generator, HV output cable, ground cable, discharge rod, user manual, and a rugged transport case. On-site installation, commissioning, and operator safety training are available upon request. Spare parts including discharge gaps, capacitors, and HV diodes are stocked for rapid replacement.