logo
Home > Products >
AC DC Hipot Tester
>
XHDP-80M 80 kV VLF AC Hipot Tester with Touchscreen for 35 kV Cable and Motor Testing

XHDP-80M 80 kV VLF AC Hipot Tester with Touchscreen for 35 kV Cable and Motor Testing

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: CE/ISO
Model Number: XHDP-80M
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE/ISO
Model Number:
XHDP-80M
Output Voltage:
30-80kV Peak
Output Frequency:
0.1Hz-0.01Hz Auto Variable
Load Capacity:
<=6uF (within 50kV); <=4uF (above 50kV)
Voltage Resolution:
0.1kV
Voltage Accuracy:
3%
Current Resolution:
0.1mA
Current Accuracy:
3%
Waveform Distortion:
<=3%
Protection Action Time:
<20ms
Input Power:
50Hz, 230V +/-5%
Booster Weight:
25kg (single) / 45kg (second Stage)
Display:
Color Touchscreen With Output Waveform
Optional Functions:
DC / Dielectric Loss / Partial Discharge Test
Highlight:

High Light

Highlight:

XHDP-80M VLF Hipot Tester

,

80kV Ultra Low Frequency Generator

,

0.1Hz Cable Motor Withstand Test

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description
Touchscreen VLF Hipot Tester

XHDP-80M 80 kV VLF AC Hipot Tester with Touchscreen

An integrated 80 kV set for 35 kV and below XLPE cables and high voltage motors, driven entirely from one touchscreen.

30 – 80 kVpeak output
0.1 – 0.01 Hzautomatic variable frequency
≤ 6 µFload up to 50 kV
Touchscreen + USB90 records on board

Overview

The XHDP-80M is an 80 kV VLF AC hipot tester built on digital variable-frequency technology with single-chip control. Voltage boost, step-down, measurement and protection are fully automated, and the all-electronic design keeps the unit compact enough for field work. A colour touchscreen displays the output waveform directly, a USB port exports stored test records, and up to 90 results are held on board - so a 0.1 Hz withstand test on a 35 kV cable or motor can be set up, run, recorded and handed over without extra instruments.

Key specifications

ParameterSpecification
ModelXHDP-80M
Rated output voltage30 – 80 kV peak
Output frequency0.1 – 0.01 Hz, automatic variable frequency
Load capacity≤ 6 µF up to 50 kV; ≤ 4 µF above 50 kV
Voltage / current resolution0.1 kV / 0.1 mA
Voltage / current accuracy3 %
Peak voltage error≤ 3 %
Waveform distortion≤ 3 %
Protection action time< 20 ms
Test time1 – 99 minutes
Stored recordsUp to 90 tests, printable or exportable via USB
Input power50 Hz, 230 V ± 5 %
Working conditionsIndoor or outdoor, −10 °C to +40 °C, ≤ 85 % RH

Typical field workflow

  1. Connect. Wire controller, booster and test object following the wiring diagram shown on the touchscreen.
  2. Set the test. Enter test voltage from 0 to the rated value and test time from 1 to 99 minutes; the system keeps both inside the safe range.
  3. Pre-test. Two automatic cycles check for low-resistance faults and measure specimen capacitance before the test voltage is applied.
  4. Test and hand over. The set steps up at the correct frequency with protection active, discharges the specimen automatically at stop, then prints the result or exports it over USB from the 90-record store.

Why crews choose this set

Two boosters that work aloneRatings above 60 kV use a series structure in which each booster can also be used independently, so one set covers more than one voltage class.
No protection values to setOver-voltage and over-current limits are derived from the specimen capacitance and test voltage, with reaction to sudden changes in under 20 ms.
No capacitance-rise effectClosed-loop negative feedback keeps the output stable as specimen capacitance changes.
Sampling on the high sideVoltage and current are read where the specimen sees them, at 0.1 kV and 0.1 mA resolution and 3 % accuracy.
150 kV output leadThe high voltage lead supplied with the set is rated well above the unit's own output.
One screen, one cableTouchscreen operation for setup and waveform review, USB for moving records into a test report.

Who it is built for

Cable erection and installation contractors, urban distribution network operation and maintenance crews, industrial plant electrical departments, and wind, solar and energy storage station O&M teams carrying out AC withstand voltage commissioning and preventive testing on 35 kV and below XLPE power cables and high voltage motors.

For distributors, EPC contractors and testing service companies, the set ships in export packing with technical support - which suits buyers who must test long cable runs without moving a 50 Hz power-frequency test system between sites.

Standard and customized configurations

The standard configuration is the 30 – 80 kV automatic-sweep unit described above. DC output, dielectric loss and partial discharge diagnostics are available on customized configuration, and dielectric loss limits are not stated in the standard table because they depend on the agreed configuration.

Frequently asked questions

Who is this set designed for?

Cable installation contractors, urban distribution network O&M crews, industrial plant electrical departments and renewable energy station maintenance teams performing AC withstand voltage commissioning and preventive testing on 35 kV and below XLPE cables and high voltage motors.

What test voltage and cable types does it support?

An adjustable 30 – 80 kV peak output at 0.1 – 0.01 Hz, mainly for AC withstand testing of power cables and motors rated 35 kV and below, with load capacity up to 6 µF within 50 kV and 4 µF above 50 kV.

How long is the test and how are results kept?

Test time is adjustable from 1 to 99 minutes, with 60 minutes the usual duration under cable test codes. Up to 90 records are stored on board, and each one can be printed or exported through the USB port.

What protection does it provide?

Over-voltage, over-current, sudden-change and discharge protection acting in under 20 ms, derived automatically from the test parameters, with automatic discharge of the specimen at stop.

How does it differ from a conventional 50 Hz hipot tester?

The 0.1 Hz output lowers the reactive charging current sharply, so a compact set can test long cable runs that would otherwise need a heavy power-frequency system.

Request pricing or a demonstration

XZH TEST manufactures cable fault location and high voltage test equipment to IEC and ISO quality standards, with a 12-month warranty and lifetime technical support. Send your cable class and per-phase capacitance for a configuration check.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this product

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.