An integrated 80 kV set for 35 kV and below XLPE cables and high voltage motors, driven entirely from one touchscreen.
The XHDP-80M is an 80 kV VLF AC hipot tester built on digital variable-frequency technology with single-chip control. Voltage boost, step-down, measurement and protection are fully automated, and the all-electronic design keeps the unit compact enough for field work. A colour touchscreen displays the output waveform directly, a USB port exports stored test records, and up to 90 results are held on board - so a 0.1 Hz withstand test on a 35 kV cable or motor can be set up, run, recorded and handed over without extra instruments.
| Parameter | Specification |
|---|---|
| Model | XHDP-80M |
| Rated output voltage | 30 – 80 kV peak |
| Output frequency | 0.1 – 0.01 Hz, automatic variable frequency |
| Load capacity | ≤ 6 µF up to 50 kV; ≤ 4 µF above 50 kV |
| Voltage / current resolution | 0.1 kV / 0.1 mA |
| Voltage / current accuracy | 3 % |
| Peak voltage error | ≤ 3 % |
| Waveform distortion | ≤ 3 % |
| Protection action time | < 20 ms |
| Test time | 1 – 99 minutes |
| Stored records | Up to 90 tests, printable or exportable via USB |
| Input power | 50 Hz, 230 V ± 5 % |
| Working conditions | Indoor or outdoor, −10 °C to +40 °C, ≤ 85 % RH |
Cable erection and installation contractors, urban distribution network operation and maintenance crews, industrial plant electrical departments, and wind, solar and energy storage station O&M teams carrying out AC withstand voltage commissioning and preventive testing on 35 kV and below XLPE power cables and high voltage motors.
For distributors, EPC contractors and testing service companies, the set ships in export packing with technical support - which suits buyers who must test long cable runs without moving a 50 Hz power-frequency test system between sites.
Cable installation contractors, urban distribution network O&M crews, industrial plant electrical departments and renewable energy station maintenance teams performing AC withstand voltage commissioning and preventive testing on 35 kV and below XLPE cables and high voltage motors.
An adjustable 30 – 80 kV peak output at 0.1 – 0.01 Hz, mainly for AC withstand testing of power cables and motors rated 35 kV and below, with load capacity up to 6 µF within 50 kV and 4 µF above 50 kV.
Test time is adjustable from 1 to 99 minutes, with 60 minutes the usual duration under cable test codes. Up to 90 records are stored on board, and each one can be printed or exported through the USB port.
Over-voltage, over-current, sudden-change and discharge protection acting in under 20 ms, derived automatically from the test parameters, with automatic discharge of the specimen at stop.
The 0.1 Hz output lowers the reactive charging current sharply, so a compact set can test long cable runs that would otherwise need a heavy power-frequency system.
XZH TEST manufactures cable fault location and high voltage test equipment to IEC and ISO quality standards, with a 12-month warranty and lifetime technical support. Send your cable class and per-phase capacitance for a configuration check.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews