XHJB666 Microcomputer Relay Protection Tester — a 6-phase secondary injection relay test set with 6 voltage and 6 current output channels, 0–30 A per phase, 0.2 class output accuracy and an 8.4-inch colour TFT display. Modular linear power amplifier and DSP controlled output stage, built for protection relay verification, panel commissioning and periodic calibration in substations, power plants and relay test laboratories.
| Current output (per phase) | 0–30 A, accuracy class 0.2 |
|---|---|
| 6-phase parallel current output | 0–180 A |
| Output duration | 0–5 A continuous; 5–10 A ≥ 45 s; 10–20 A ≥ 5 s |
| Maximum output power per current phase | 250 VA |
| AC voltage output | 6 × 120 V (single phase) |
| AC voltage output power | ≥ 60 VA per phase |
| DC current | ± 5 A per phase, power ≥ 100 VA |
| DC voltage | ± 150 V per phase, power ≥ 100 VA |
| Frequency range | 1–1000 Hz, frequency resolution 1 mHz |
| Harmonic order | 2nd – 20th |
| Binary inputs | 10 channels, potential free or 0–250 V potential contacts, auto recognised |
| Binary outputs | 8 channels |
| Display | 8.4-inch high resolution colour TFT LCD with embedded industrial PC |
| Auxiliary DC supply | Independent adjustable 110 V and 220 V |
| Power supply | 220 V ± 10 percent, 50 Hz ± 10 percent |
Output accuracy class 0.2 refers to the current and voltage output channels of the tester. In protection relay verification the effective accuracy of a test depends on the complete loop, including tester output, test leads, relay burden and the measurement reference, so the class rating should always be read together with the load range of each channel.
Current channels are rated for 0–30 A per phase continuously up to 5 A, with 6-phase parallel output reaching 0–180 A. Frequency is adjustable from 1 Hz to 1000 Hz in 1 mHz steps, and harmonic content can be superimposed from the 2nd to the 20th order for harmonic restraint and blocking tests.
Wooden case filled with foamMinimum order 1 unitDelivery 5–8 daysPayment T/TWarranty 12 monthsSupply ability 2000 PCS per year
Each unit is packed in a wooden case filled with foam for export handling, and supplied with a warranty certificate. Customisation of output configuration, branding and panel language is available on request. The tester is produced under an ISO certified quality system, and test requirements for IEC relay families should be confirmed with us before ordering so that the correct configuration is quoted.
What is the difference between a 6-phase and a 3-phase relay test set
A 3-phase set covers most distribution and industrial protection relays. A 6-phase set adds a second three-phase group, so both ends of a line differential relay can be driven, 6-phase voltage schemes can be tested and 12 channels are available from one instrument. The XHJB666 can also be switched to 4-voltage 3-current mode when a conventional configuration is sufficient.
Can this tester be used on digital substation relays with IEC 61850 GOOSE and SV
The XHJB666 is a secondary injection tester with 6 voltage and 6 current channels plus binary inputs and outputs. For GOOSE and sampled value based testing, please send us your relay list so the required configuration can be confirmed before ordering.
What is the minimum order quantity and delivery time
Minimum order quantity is 1 unit. Standard delivery time is 5–8 days and payment terms are T/T. Supply ability is 2000 PCS per year.
Is customisation available
Yes. Output configuration, branding, panel language and packing can be customised. Send us your test requirement list and the configuration and lead time will be confirmed.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews