logo
Home > products >
AC DC Hipot Tester
>
Customizable AC Withstand Voltage Series Frequency Conversion Resonance Test Device XHBP

Customizable AC Withstand Voltage Series Frequency Conversion Resonance Test Device XHBP

Product Details:
Detail Information
Model NO.:
XHBP
Customized:
Customized
Rated Output Voltage:
500kv And Below
Output Frequency:
20~300Hz
Maximum Test Capacity:
1000kVA And Below
Transport Package:
Exported Wooden Case
Trademark:
XZH TEST
Origin:
China
Customization:
Available
Warranty:
12 Months
Power:
Electricity
Product Description


Product Description

The XHBP series frequency conversion resonance test device is mainly designed and manufactured for the AC withstand voltage test of primary electrical equipment for substations of 220kV and below. It can meet the AC withstand voltage test of capacitive equipment such as transformer, GIS system, SF6 switch, cable and casing according to the regulations. This series of devices is mainly composed of variable frequency control power supply, excitation transformer, reactor and capacitor voltage divider. After the capacitor divider, the rectifier silicon stack is connected to complete the DC withstand voltage test of the device.

Detailed Photos


Customizable AC Withstand Voltage Series Frequency Conversion Resonance Test Device XHBP 0 

Product Parameters

Main Features:

  1. Reactors of the same voltage class and same capacity are smaller in size and lighter in weight;
  2. The temperature rise is small at rated load;
  3. Dry epoxy casting, high mechanical strength, good electrical insulation performance, beautiful and reliable;
  4. The frequency conversion control source has a large capacity margin;
  5. Strong protection function; good output waveform; good stability;
  6. With a variety of working modes, easy to operate; 220V or 380V single-phase power supply, convenient for on-site power
Main Specifications:
  1. Rated output voltage: 500kV and below (AC RMS); output frequency: 20 ~ 300Hz;
  2. Resonant voltage waveform: pure sine wave, waveform distortion rate <1.0%;
  3. Maximum test capacity: 1000kVA and below;
  4. Working time: under full power output, one continuous working time is 60min; quality factor: 30~90;
  5. Frequency adjustment: sensitivity: 0.1Hz, instability: <0.05%;
  6. Working power supply: 380/220V ± 15% / 50Hz ± 5%; 

Model:
XHBP-44/44(10kV300mm² cable 1km)
XHBP-88/44(10kV300mm² cable 2km)
XHBP-216/108(10kV300mm² cable 2km, 35kV300mm² cable 0.5km, 35kV power transformer/switch)
XHBP-270/108(10kV300mm² cable 6km, 35kV300mm² cable 2km)
XHBP-405/108(10kV300mm² cable 8km, 35kV300mm² cable 2.5km, 10-35kV transformer, switch)
XHBP-675/270(10kV300mm² cable 10km, 35kV300mm² cable 4km, 110kV400mm² cable 1km, 10-35kV transformer, GIS)
XHBP-135/108/54(10kV300mm² cable 3km, 35kV300mm² cable 1km   35kV power transformers, circuit breakers, switches, insulators, etc.)
XHBP-405/270(10kV300mm² cable 3km, 35kV300mm² cable 1.5km, main transformer below 110kV, GIS, circuit breaker, bus, etc.)
XHBP-405/270(10kV300mm² cable 5km, 35kV300mm² cable 2km  Main transformer, GIS, circuit breaker, bus bar, switch below 110kV)
XHBP-800/400(10kV300mm² cable 4km, 35kV300mm² cable 1km  Main transformers, GIS, circuit breakers, switches, etc. below 220kV)
XHBP-1000/500(35kV300mm² cable 3km, 110kV300mm² cable 0.1km, current and voltage transformer below 220kV; main transformer, GIS, circuit breaker, switch below 220kV)
XHBP-1000/500(110kV400mm²0.8km, 220kV400mm² cable 0.5km, main transformer below 35-500kV, GIS, insulator, switch)