logo
Home > products >
Cable Fault Locator
>
Cable Fault Simulation System for Open circuit Short circuit High resistance Low resistance

Cable Fault Simulation System for Open circuit Short circuit High resistance Low resistance

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHGG510
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHGG510
Rated Voltage Of Analog Cable:
DC 35kV
Remote Control Distance:
10M
Continuous Working Time:
8 Hours
Size:
860mm* 660mm*2030mm
Weight:
300KG
Ambient Temperature:
-30℃~ +70℃
Relative Temperature:
RH≤85% (25℃)
Altitude:
H≤1000m
Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
8-15 days
Payment Terms:
T/T
Supply Ability:
1000 PCS/Year
Product Description


XZH TEST XHGG510 Cable Fault Simulation System for Open circuit Short circuit High resistance Low resistance

Cable Fault Simulation System for Open circuit Short circuit High resistance Low resistance 0


XHGG510 cable fault simulation system can simulate all types of power cable faults such as open circuit, short circuit, high resistance, low resistance, flashover, leakage, joint, etc. It is mainly used for training power cable detection personnel in various industries.


Cable Fault Simulation System for Open circuit Short circuit High resistance Low resistance 1

Main functions

1. 12.1-inch industrial all-in-one machine with centralized control and touch screen operation;

2. Can simulate near-end and far-end low-resistance fault waveforms;

3. Can simulate near-end and far-end short-circuit fault waveforms;

4. Can simulate near-end and far-end open-circuit fault waveforms;

5. Can simulate near-end and far-end leakage high-resistance fault waveforms;

6. Can simulate near-end and far-end flashover high-resistance fault waveforms;

7. Can simulate intermediate joints and T-type, X-type joint waveforms;

8. All fault simulations, no manual switching, just select the combined fault type, the device automatically completes the internal fault simulation conversion, to achieve true intelligence.

9. This device has VGA output and can be connected to various display devices.

Technical parameters

1. The number of simulated fault waveforms is not less than 40

2. Near-end faults are tens of meters, and far-end faults are hundreds of meters

3. Low-resistance fault simulator: 0 ohm~hundred ohm level

4. Open circuit fault simulator: G ohm~infinity

5. Leakage high-resistance fault simulator: k ohm level~hundred M ohm level

6. Flashover high-resistance fault simulator: flashover voltage range is several kV~tens of kV

7. 2500V megohmmeter insulation resistance
a. Open circuit state is greater than 1.5GΩ
b. Short circuit state: 0 MΩ
c. Low resistance state is about 5MΩ
d. Leakage state is about 2MΩ
e. Flashover state is about 1GΩ

8. Rated voltage of simulated cable: DC 35kV

9. Remote control distance: 10 meters

10. Continuous working time: 8 hours

11. Cabinet size: 860mm long × 660mm wide × 2030mm high

12. Cabinet weight: 300KG

13. Use conditions:
a. Ambient temperature -30℃~ +70℃
b. Relative temperature RH≤85% (25℃)
c. Altitude h≤1000m