Product Details:
Place of Origin: China
Brand Name: XZH TEST
Certification: CE, ISO
Model Number: XHDD503B
Detail Information
Place of Origin:
China
Brand Name:
XZH TEST
Certification:
CE, ISO
Model Number:
XHDD503B
Product Name:
Underground Cable Fault Pinpoint Locator
Test Frequency:
100Hz~1500Hz
Maximum Signal Gain:
>=100dB
Fixed Point Accuracy:
0.1m
Battery:
8.4V 2.4Ah Lithium-Ion
Use Time:
Continuous Use Time > 8 Hours
Charger:
Input AC220V±10%, 50Hz; Nominal Output 8.4V, 1A
Display:
5-inch Color LCD 854×480 Touch
Working Conditions:
3. -20℃ -65 ℃, Relative Humidity ≤ 90 %, Altitude <4500m
Weight:
7kg
Test Frequency:
100Hz-1500Hz
Maximum Signal Gain:
≥100dB
Acoustic-Magnetic Time Difference:
Max 80ms
Continuous Use:
>8 Hours
Charging Time:
<6 Hours
BNR Noise Reduction:
Supported
Sound Trigger Threshold:
Adjustable
Magnetic Trigger Threshold:
Adjustable
Working Temperature:
-10℃~55℃
Warranty:
12 Months
Highlight:

High Light

Highlight:

100dB Gain Acoustic-Magnetic Synchronization

,

0.1m Precision Digital Fault Location

,

8-Hour Portable Lithium Battery Field Unit

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description
Digital Acoustic-Magnetic Synchronization Cable Fault Pinpointer — Portable Precision Field InstrumentProduct Overview

The XHDD503B is a digital acoustic-magnetic synchronous cable fault pinpointer engineered for power cable fault emergency repair operations. Designed to operate in conjunction with a high-voltage signal generator, this portable intelligent device integrates acoustic-magnetic time difference positioning technology, BNR background noise reduction, and path auxiliary detection into a single 7kg field unit.

With a maximum signal gain of 100dB and 0.1m fixed-point accuracy, the XHDD503B delivers precise fault location across multiple test modes. The 5-inch color touch LCD (854×480 resolution) provides clear real-time waveform display with automatic acoustic-magnetic time difference calculation up to 80ms. Bar graph indicators for both sound and electromagnetic signal strength, combined with adjustable trigger thresholds, enable operators to efficiently and accurately complete cable fault pinpointing in demanding field conditions.

XHDD503B Detail Photos
Key Features
  1. Acoustic-magnetic synchronization with 100dB maximum signal gain for deep fault detection.
  2. 0.1m fixed-point accuracy with automatic and manual acoustic-magnetic time difference analysis (max 80ms).
  3. BNR background noise reduction mode enhances signal clarity in noisy field environments.
  4. 5-inch color LCD touch screen with 854×480 resolution for clear waveform visualization.
  5. Dual bar graph indicators for real-time sound and electromagnetic signal strength monitoring.
  6. Adjustable sound and magnetic field trigger thresholds with trigger prompt functionality.
  7. Multiple filter modes: All-pass, Low-pass, High-pass, and Band-pass for adaptable signal processing.
  8. Built-in 8.4V 2.4Ah lithium-ion battery pack delivers over 8 hours of continuous field operation.
  9. Records the last acoustic-magnetic time difference measurement for subsequent analysis and documentation.
  10. Compact 7kg design with intuitive touch interface for single-operator field deployment.
Technical Specifications
Acoustic-Magnetic Synchronization Performance
Sound Channel Bandwidth (All-pass) 100Hz ~ 1500Hz
Low-pass Filter 100Hz ~ 400Hz
High-pass Filter 150Hz ~ 1500Hz
Band-pass Filter 200Hz ~ 600Hz
Maximum Signal Gain ≥100dB
Fixed Point Accuracy 0.1m
Acoustic-Magnetic Time Difference Range Max 80ms
BNR Noise Reduction Supported
Display & Control
Display Type 5-inch Color LCD Touch Screen
Resolution 854 × 480
Sound Signal Indication Bar Graph with Adjustable Trigger Threshold
Electromagnetic Signal Indication Bar Graph with Adjustable Trigger Threshold
Power & Physical
Battery 8.4V 2.4Ah Lithium-Ion Pack
Continuous Operation > 8 Hours
Charger Input AC 220V ±10% / 50Hz
Charger Output 8.4V / 1A
Charging Time < 6 Hours
Weight 7 kg
Environmental
Operating Temperature -10℃ ~ 55℃
Relative Humidity 5% ~ 90% RH
Altitude < 4500m
Working Principle Acoustic-Magnetic Time Difference Positioning

When the high-voltage signal generator applies impulse voltage to the fault cable, discharge at the fault point generates both acoustic and electromagnetic signals. The electromagnetic signal propagates at near light speed, while the acoustic signal travels at approximately 340m/s through soil. The XHDD503B measures the time difference between these two signal arrivals. As the operator moves the sensor along the cable path, the point with the minimum acoustic-magnetic time difference indicates the exact fault location directly below. The system supports both automatic calculation and manual waveform analysis, with a maximum measurable time difference of 80ms.

BNR Background Noise Reduction

Field environments often present high levels of ambient noise from traffic, machinery, and weather conditions. The XHDD503B's BNR (Background Noise Reduction) mode employs advanced digital filtering to isolate the characteristic discharge sound from background noise, significantly improving the signal-to-noise ratio. Combined with the adjustable sound trigger threshold, operators can precisely tune the detection sensitivity to match field conditions.

Application Scenarios
  • Precision fault location for low-resistance, short-circuit, open-circuit, and disconnection faults in power cables.
  • High-resistance leakage and flashover fault pinpointing in underground distribution networks.
  • Emergency repair operations for urban power cable faults with minimal excavation requirements.
  • Routine maintenance inspection of cable routes in utility substations and industrial facilities.

Operational Note: The XHDD503B is designed for use with a compatible high-voltage signal generator. For optimal results, ensure proper grounding and follow the instrument operating procedures detailed in the user manual. The built-in lithium battery should be charged every 2 months during extended storage periods to maintain battery health.