logo
Home > Products >
Cable Fault Locator
>
High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

Product Details:
Place of Origin: China
Brand Name: XZH TEST
Certification: CE ISO
Model Number: XHGG502
Detail Information
Place of Origin:
China
Brand Name:
XZH TEST
Certification:
CE ISO
Model Number:
XHGG502
Highlight:

High Light

Highlight:

underground cable fault locator

,

high voltage cable tester

,

power cable fault detection system

Trading Information
Minimum Order Quantity:
1 set
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description

High Voltage Cable Fault Locator System | XHGG502

The XHGG502 high voltage cable fault locator system uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.

Applications & Target Audience: Engineered for urban underground power cable network operators, high-voltage cable fault repair and maintenance service companies, large industrial and mining facility electrical departments, and power engineering contractors that pinpoint main insulation faults on 35kV and below underground power cables.

Key Specifications

No.ParameterSpecification
1Filter parametersAll-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz.
2Channel gain8 levels adjustable.
3Magnetic channel gain8 levels adjustable.
4Output gain16 levels (0~112db)
5Output impedance350Ω
6Acoustomagnetic positioning accuracyless than 0.2m.
7Path identification accuracyless than 0.5m.
8Power supply4*18650 standard lithium batteries.
9Standby timemore than 8 hours.
10Volume428L×350W×230H
11Screen pixels854-480
12Brightness800nit
13Transmission speed unit0-100ms
14Accuracy1ms
15Sound bandwidth100-1.6khz
16Magnetic coil bandwidth100-20kHZ
17Both sound and magnetism aregreater than 75db
18Weight6.5kg.
19Ambient temperature-25~65ºC; Relative humidity: ≤90%.

Complete Cable Fault Location Workflow

Step 1 - Pre-location: Roughly test the cable fault distance with the reflectometer XHGG502 based on the low-voltage pulse reflection method (TDR), high voltage flashover method (ICE, DECAY) and arc reflection pulse reflection method (ARC single shot and ARC multi-shot).

Step 2 - Pinpointing: Use the acoustic and magnetic synchronization method to precisely locate the fault point within the rough measurement range, with an acoustomagnetic positioning accuracy of less than 0.2m.

Step 3 - Verification: Calibrate the cable length, confirm the fault condition by auditory and visual judgment, and record the acoustic and magnetic time difference for the test report.

Operation Panel Introduction

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;

2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;

3 Display: 5-inch touch display.

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

1 Sensor: Probe sensor connection port;

2 Charging: charger connection port;

3 Dedicated headphone jack.

Packing List

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

Application Scenarios

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502 High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; roughly test cable fault distance.

Pre-locating cable faults with the reflectometer XHGG502 based on the low-voltage pulse reflection method (TDR), high voltage flashover method (ie. ICE, DECAY), arc reflection pulse reflection method (ARC single shot and ARC multi-shot). Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method (TDR), and high-voltage decay (flashover) method (DECAY), arc reflection method (single-shot/ multi-shot).

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

There are three test mode of XHGG502, low voltage pulse, high voltage flashover, ARC multi-shot.

The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502.

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502.

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

New version   New version

The XHHV535-2L high-voltage pulse generator is mainly used for shock discharge during cable fault test. It can also be used for DC withstand voltage test of other electrical equipment. This device integrates DC high voltage source, energy storage capacitor, discharge ball gap, etc. This device completely replaces the traditional hundreds of kilograms of test transformers, operation boxes and pulse energy storage capacitors (generally a set of 5kVA transformers are more than 60 kilograms, control box is more than 30 kg, and the pulse energy storage capacitor is more than 20 kg). The power supply adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, which makes the whole machine simple in structure and ultra-light in weight. In order to retain people's habit of using transformers and operation boxes to generate DC high voltage, this pulse generator adopts humanized design and operation mode, which is safe and reliable. Really achieve the effect of not being damaged by impact, and the short circuit of high voltage to ground can also work normally. It is currently the lightest and most user-friendly portable DC shock high-voltage equipment. It is an ideal product for power cable fault detection.

Product Features

★ With over-current, over-voltage, overheating automatic protection function;

★ With DC withstand voltage, impact discharge function;

★ The high-voltage pulse output is uniform and controllable;

★ Super short-circuit protection function, which can make the high-voltage output directly short-circuit to the ground;

★ It has dual 2.5-level pointer meters for current and voltage display, which is intuitive and clear, and it is clear at a glance whether the fault point is fully discharged, and the discharge process is reflected in real time;

★ High-voltage side voltage measurement.

Technical Data

ParameterSpecification
Impulse voltage0-35kV
High voltage partial pressure2.5 class
Built-in capacitor2μF
Discharge power0~1225J
Output voltage polaritynegative polarity
Over-current protection8mA (more than 3 seconds)
Impact power400W
Over temperature protection85ºC
Volume(mm)540L×300W×450H
Weightno more than 25kg
no more than 25kgAC 220V±10%/50Hz±2Hz
Ambient temperature-20~+60ºC

Panel Introduction

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

1 Safety ground: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified.

2 High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to prevent high-voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.

3 Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled under the high-voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).

4 Discharge button: Press this button to make contact with the ball gap, and discharge manually. (The duration of each key press cannot exceed 1s).

5 High voltage start button: When the start button light is on, it means that the voltage output is in the zero position. When the light is on, the start button is valid. If the start button light is not on after turning on the power switch, turn the voltage adjustment knob counterclockwise until the light is on. When the button light is on, press this button to start the device and generate high voltage output.

6 High-voltage stop button: When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, the high-voltage light goes out, and the internal discharge ball stops working. When the stop key is on, it means there is high voltage output, and when it is off, it means there is no high voltage output.

7 Over-current protection switch: When pressed, it means that the over-current protection function has started; when it is popped up, it means that the instrument has triggered the over-current protection.

8 Voltage adjustment: After turning on the device, you must first turn the knob counterclockwise to the end, press the start button, and then adjust clockwise to increase the output high voltage from small to large, and adjust counterclockwise to reduce the output high voltage from large to small.

9 Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns off the system power.

10 The fuse holder: the place where the fuse of the AC 220V power supply system is installed.

11 Power socket: the working power supply of the instrument, AC 220V connection port.

12 Time setting: Set the discharge time interval.

13 Ammeter: indication of the current on the high voltage side.

14 Voltmeter: high voltage output voltage indicating kV meter.

15 High-voltage output (EMP): When impacting discharge, connect the high-voltage output line.

16 High voltage output (DC): When DC withstand voltage, connect the high voltage output line.

Packing List

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

Application - Underground Cable Fault Location

High Voltage Cable Fault Locator XHGG502 Acoustic Magnetic Synchronization Pinpointer 35kV Underground Power Cable Tester | XHGG502

We are a professional manufacturer of cable fault detection equipment, we can customize the special technical solution for you.

FAQ

Q1: Who is this high voltage cable fault locator system designed for?

It is designed for urban underground power cable network operators, high-voltage cable fault repair and maintenance service companies, large industrial and mining facility electrical departments, and power engineering contractors that pinpoint main insulation faults on 35kV and below underground power cables.

Q2: What cable fault types can the XHGG502 system locate?

It accurately and quickly detects the main insulation failure of power cables with voltage levels of 35kV and below, calibrates the cable length, and roughly tests the cable fault distance, covering low-resistance, open-circuit, disconnection, high-resistance leakage and flashover faults.

Q3: How does the acoustic and magnetic synchronization method work?

The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment while collecting the acoustic and magnetic time difference, with an acoustomagnetic positioning accuracy of less than 0.2m.

Q4: What test modes are available on the XHGG502?

There are three test modes: low voltage pulse, high voltage flashover, and ARC multi-shot. The low voltage pulse mode does not require a high-voltage pulse generator, while the other modes must be used in conjunction with a high-voltage pulse generator such as the XHHV535-2L.

Q5: What is included in the complete fault location system?

The complete system covers the XHGG502 reflectometer with acoustic and magnetic pinpointer, the XHHV535-2L high-voltage pulse generator with 0-35kV impulse voltage and 0~1225J discharge power, probe sensors, dedicated headphones, charger, and connection accessories, all packed in wooden packaging for safe transport.

Welcome you contact us for more information.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

A
Abdullah Al Dhaheri
United Arab Emirates Jun 9.2026
Used this cable locator for 4 months on DEWA utility projects. Works well even in 45°C summer heat — no overheating issues. Depth readings accurate, multiple frequencies helpful for busy urban areas. Battery lasts full shift.Overall: Solid value for money. Recommended for utility and construction teams in Gulf region.
R
Ravi Verma
India May 6.2026
Bhai, this pulse generator is total game changer for our discom team. Six months heavy use across Uttar Pradesh — heat, dust, monsoon humidity, still going strong. Fault detection is spot on, saves us hours of digging every time. Build is tough, no-nonsense. And the price? Forget those fancy foreign brands charging 3x more. This is proper value for money. Our linemen love it. Must buy for any electricity department. Jai power!
R
R*s
United Kingdom Apr 14.2026
It works great and offers excellent value for money—it accurately pinpoints the fault every time, guys.