The Cable Fault Locator XHDD503B employs the acoustic and magnetic synchronization method to pinpoint the location of power cable faults. The device uses an impact discharge generator to create electronic flashovers, which are then detected and amplified by a specialized probe. The precise location of the fault is determined through auditory and visual cues.
This instrument not only completes the precise positioning of cable faults within a pre-determined range but also collects the time difference between acoustic and magnetic signals. It integrates advanced positioning technology with path-assisted testing, offering multiple test modes and a variety of informative prompts to efficiently and accurately locate cable faults.
|
Acoustic-magnetic synchronous fixed-point function
|
||
|
Acoustic-magnetic synchronous fixed-point function
|
Sound channel |
a) Bandwidth All pass: 100Hz~1500Hz. Low pass: 100Hz~400Hz. Qualcomm: 150Hz~1500Hz. Band pass: 200Hz~600Hz. b) Maximum signal gain: >=100dB. c) Fixed-point accuracy: 0.1m.
|
|
Magnetic field channel |
Maximum signal gain: >=100db
|
|
|
Acoustomagnetic transit time positioning mode: waveform display, acoustic and magnetic transit time display. |
||
|
Signal gain: adjustable from 1 to 8 levels. |
||
|
Magnetic field channel: adjustable from 1 to 8 levels |
||
|
Sound signal strength bar graph indicates, and the sound trigger threshold (0 to 99 levels) is adjustable. |
||
|
The electromagnetic signal strength is indicated by a bar graph, the magnetic field trigger threshold (0 to 99 levels) is adjustable, and it has a magnetic field trigger prompt function. |
||
|
Electromagnetic signal strength bar graph indication, adjustable magnetic field trigger threshold, with magnetic field trigger prompt function.
|
||
|
Acoustic-magnetic time difference positioning mode: waveform display, the maximum acoustic-magnetic time difference is 80ms, which can be automatically calculated and manually analyzed; it can record the last time acoustic-magnetic time difference.
|
||
|
Power supply:
|
a) Battery: built-in lithium-ion battery pack, voltage 8.4V, capacity 2.4Ah b) Use time: continuous use time > 8 hours; c) Charger: input AC220V±10%, 50Hz; nominal output 8.4V, 1A d) Charging time: <3 hours.
|
|
|
Display mode: 5-inch color LCD, 854*480 resolution, with touch function. |
||
|
Operating environment temperature: -20°C-65°C, humidity ≤90% RH, altitude <4500m. |
||
| Application Scenario | Typical Cable Faults |
|---|---|
| Street Lighting Networks | Open circuit, disconnection and leakage faults in buried street light cables |
| Telecommunication & Coaxial Networks | High-frequency coaxial cable faults and buried communication line breaks |
| Industrial Plants & Mining Sites | Low-resistance, short-circuit and high-resistance flashover faults in power cables |
| Municipal Utility Contractors | Leakage and sheath faults in underground power distribution cables |
Thanks to its small, portable and lightweight design with a built-in high-capacity lithium battery, the XHDD503B can be carried directly to the fault zone and deliver accurate pinpointing results within minutes on site.
![]()