Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Product Details:
Place of Origin: Xi'an ShanXi
Brand Name: XZH TEST
Certification: ISO/CE
Model Number: XHGG501C
Detail Information
Place of Origin:
Xi'an ShanXi
Brand Name:
XZH TEST
Certification:
ISO/CE
Model Number:
XHGG501C
Highlight:

High Light

Highlight:

Rough Fault Distance Cable Fault Locator

,

Low Voltage TDR Cable Tester

,

TDR Technology Cable Fault Detector

Trading Information
Minimum Order Quantity:
1set
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
3000unit/year
Product Description
XHGG501C LV TDR Cable Fault Locator
The LV TDR cable fault locator provides rough fault distance measurement for low voltage cables, enabling quick identification of cable issues.
Key Features
Accurate rough fault distance measurement
Designed for low voltage cable systems
Time Domain Reflectometry (TDR) technology
Quick fault identification capability
Pulse width 0.2uS/2uS
minimum resolution 1.0M
Test blind spot ≤35m
Distance range ≥16km


Regarding waveforms


1. Standard waveform for open circuit fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (but can also be negative); at time t2, the reflected pulse waveform from the intermediate joint in the cable (reflected waves from joints are generally of the same polarity, but this depends on the joint structure); at time t3, the reflected pulse waveform from an open-circuit fault is positive and of the same polarity (the polarity of the fault waveform is the same as the polarity of the pulse wave generated by the instrument); at time t4, the secondary reflected pulse waveform from the open-circuit fault. Due to pulse attenuation, the secondary reflected wave at time t4 has a smaller amplitude than the primary reflected wave at time t3. The distance S from the fault point to the measuring end is... In actual operation, by moving the cursor, the instrument will automatically display and calculate the distance to the fault point.


2. Standard waveform for low impedance fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (or negative); at time t2, the reflected waveform from the intermediate joint in the cable is shown; at time t3, the reflected waveform from the low-resistance fault point is negative, representing a reflection with opposite polarity (opposite to the pulse waveform generated by the instrument); at time t4, the reflected waveform from the cable terminal is shown. The distance from the fault point to the measuring end is also considered.

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Ratings & Review

Overall Rating

4.5
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
50%
4 stars
50%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

T
Todd Richardson
United States Sep 2.2026
I’ve been running the XHZS506YS out in Phoenix, AZ. One of our guys nearly got burned bad because he didn’t verify if the buried cable was energized. This thing’s live‑voltage alert saved us from a serious safety incident. Fault pinpointing is quick, holds up great in the brutal desert heat. Keeps our crew protected and slashes troubleshooting time. Absolute must‑have tool for every field tech on our team.
Γ
Γιώργος Κωνσταντίνου
Greece Jul 15.2026
Ο εντοπιστής σφαλμάτων XHDD503C+ δουλεύει πολύ καλά για την ιδιωτική μας ομάδα. Βρήκαμε γρήγορα βλάβη σε υπόγειο καλώδιο στη Θεσσαλονίκη. Έχει μεγάλη ακρίβεια, αντέχει τις δύσκολες συνθήκες στο πεδίο και μας μείωσε πολύ τις εκσκαφές. Το προτείνω ανεπιφύλακτα!