XHHV515-8L High Voltage Surge Generator
The XHHV515-8L high voltage surge generator fully complies with DL/T846-2016 “General Technical Conditions for High-Voltage Test Equipment” and DL/T474-2017 “Implementation Guidelines for Field Insulation Tests”. Designed for shock discharge during cable fault testing, it also performs DC withstand voltage tests on other electrical equipment. By integrating the DC high-voltage source, energy storage capacitor and discharge ball gap into one portable unit, this generator completely replaces traditional test transformer systems that weigh hundreds of kilograms — making it the ideal field companion for contractors who locate faults on 10kV and below power cables.
Applications & Target Audience: Engineered for electrical engineering contractors, underground power cable construction and emergency repair crews, and on-site cable fault locating service teams that need a portable high-voltage impulse source to clear faults on 10kV and below distribution cables and to verify insulation integrity with DC withstand tests.
Key Specifications
| Parameter | Specification |
|---|
| Impulse Voltage | 0-15kV |
|---|
| Short Circuit Current | 0-320mA |
|---|
| Built-in Capacitor | 8μF |
|---|
| Discharge Power | 0-900J |
|---|
| Impact Power | 400W |
|---|
| DC Withstand Voltage Output | 0-10kV |
|---|
| Output Voltage Polarity | Negative polarity |
|---|
| High Voltage Divider | Class 1.5 |
|---|
| Over-current Protection | 8mA (more than 4 seconds) |
|---|
| Over-temperature Protection | 65°C |
|---|
| Working Power Supply | AC 220V±10% / 50Hz±2Hz |
|---|
| Ambient Temperature | -25°C to +65°C |
|---|
| Dimensions | 540 × 300 × 450 mm |
|---|
| Weight | ≤25 kg |
|---|
Advanced Features
- Automatic over-current, over-voltage and over-temperature (65°C) protection for worry-free field operation
- Dual functions in one unit: DC withstand voltage testing and impulse discharge for cable fault location
- Super short-circuit protection — the high-voltage output can be shorted directly to ground without damage
- Dual Class 1.5 pointer meters for current and voltage, showing the discharge process in real time
- High-voltage-side voltage measurement for real-time, accurate readings
- Zero-start protection with potentiometer zero-output interlock for safe voltage ramp-up
- Voltmeter keeps indicating capacitor voltage in the stop state, so crews can confirm full discharge before touching leads
- Discharge interval adjustable within the safe range to match site conditions
- Ultra-light integrated design (≤25kg) replaces 100kg+ transformer, control box and pulse capacitor sets
For contractors, every minute of outage costs money. The XHHV515-8L arrives on site ready to work: one unit, one operator, no crane, no separate control box — thump the fault, confirm the discharge, and hand the excavation point back to the crew.
One Unit Replaces a Traditional Three-Piece Test System
Traditional DC surge testing requires a 5kVA test transformer (over 60kg), a separate operation box (over 30kg) and a pulse energy storage capacitor (over 20kg) — more than 110kg of equipment that must be transported, wired and coordinated on every job. The XHHV515-8L collapses this system into a single 25kg instrument:
| Comparison Item | Traditional Transformer Set | XHHV515-8L |
| Total equipment weight | 110kg+ (3 separate units) | ≤25kg (1 integrated unit) |
| On-site setup | Complex wiring between transformer, control box and capacitor | Connect HV output, ground wires and power cord |
| Transport | Requires van or trolley, multiple trips | One person can carry to the job site |
| Output functions | Impulse discharge only (separate DC source needed) | Impulse discharge plus DC withstand in one unit |
| Impact resistance | Easily damaged by output short circuit | Super short-circuit protection, works normally even with HV shorted to ground |
FAQ
Q1: Who is the XHHV515-8L high voltage surge generator designed for?
It is designed for electrical engineering contractors, underground power cable construction and emergency repair crews, and on-site cable fault locating service teams that test 10kV and below distribution cables.
Q2: What output does it provide for cable fault location?
It delivers 0-15kV impulse voltage with 0-900J discharge energy from a built-in 8μF capacitor at 400W impact power, negative polarity output, plus 0-10kV DC withstand voltage output for insulation testing.
Q3: How does it protect the operator on site?
Safety features include over-current protection (8mA, more than 4 seconds), over-temperature protection at 65°C, zero-start interlock, super short-circuit protection, dual display meters, a dedicated discharge rod, and capacitor residual-voltage indication in the stop state.
Q4: How much weight does it save compared with traditional test transformers?
A traditional 5kVA transformer set exceeds 110kg (transformer over 60kg, control box over 30kg, pulse capacitor over 20kg). The XHHV515-8L integrates all functions into one ≤25kg unit that a single technician can carry.