logo
Home > Products >
Cable Fault Locator
>
ARC Multi-Pulse Cable Fault Pre-Locator 10.1-inch Touch 120km Range 400MHz Sampling XHGG502A

ARC Multi-Pulse Cable Fault Pre-Locator 10.1-inch Touch 120km Range 400MHz Sampling XHGG502A

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH
Certification: CE, ISO
Model Number: XHGG502A
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH
Certification:
CE, ISO
Model Number:
XHGG502A
Sampling Frequency:
1MHz~400MHz
Low Voltage Pulse Amplitude:
300V±15%
Ranging Range:
≥120km
Pulse Width:
0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS
Minimum Resolution:
0.07m
Test Blind Area:
≤10m
Measurement Error:
≤±(0.5%×L+1m)
Power Supply:
Charging AC110V~240V, 50Hz/60Hz
Pulse Coupler Withstand Voltage:
DC 35kV
Volume And Weight:
L358mm×W284mm×H168mm-4.7kg
Working Conditions:
Temperature -20℃~+65℃, Relative Humidity 90%, Atmospheric Pressure 750±30mmHg
Display:
10.1-inch TFT Touch, 1024×600, 280nit LED
Test Range:
≥120km
Sampling Frequency:
1MHz~400MHz
Low Voltage Pulse:
300Vpp, 8 Selectable Widths (0.15~10μs)
Pulse Coupler Rating:
DC 35kV
Test Modes:
TDR, ICE (impulse Current), ARM (arc Reflection Multi-pulse 8 Groups)
Waveform Storage:
8000+ LV/HV Records; 250+ Multi-pulse Records
Power Supply:
AC 110V~240V, 50Hz/60Hz; Built-in Lithium Battery
Dimensions:
358×284×168mm
Weight:
4.7kg
Operating Conditions:
-20℃~+65℃; ≤90% RH; 750±30mmHg
Compliance:
GB/T 18268.1; DL/T 849.1-2019; JJF1042-2020; CE; ISO
Highlight:

High Light

Highlight:

ARC multi pulse cable fault locator

,

120km cable pre locator 400MHz

,

high voltage cable fault tester

Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
Wooden case
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
500 units/month
Product Description

Flagship Model — XHGG502A. The most advanced cable fault pre-locator in the XZH product line, featuring 400MHz ultra-high-speed sampling, 120km maximum range, 0.07m minimum resolution, and exclusive ARC 8-group multi-pulse technology on a 10.1-inch industrial touch display.

The XHGG502A Cable Fault Pre-Locator is a professional-grade instrument combining three complementary test methodologies — TDR (Time Domain Reflectometry), ICE (Impulse Current), and ARM (Arc Reflection Multi-Pulse) — into a single integrated platform. Built around an industrial 10.1-inch TFT touchscreen computer with embedded system architecture, it delivers stable, reliable fault distance measurement and waveform analysis for all common cable fault types: low-resistance, short-circuit, open-circuit, disconnection, high-resistance leakage, and high-resistance flashover.

What sets the XHGG502A apart is its ARC multi-pulse capability: when paired with a pulse coupler (rated DC 35kV), it simultaneously displays 8 groups of high-voltage and low-voltage waveform comparisons, enabling technicians to visually match fault signatures against reference traces for confident, unambiguous fault distance determination — a capability typically found only in instruments costing significantly more.

Test Modes — Three Methods, One Instrument
ModeMethodBest For
TDRLow-Voltage Pulse (300Vpp, 8 pulse widths)Low-resistance, short-circuit, open-circuit, and disconnection faults. Cable length and wave speed measurement.
ICEImpulse Current (High-Voltage Flashover)High-resistance leakage and flashover faults. Captures transient discharge current waveforms.
ARMArc Reflection Multi-Pulse (8 groups)High-resistance and flashover faults with difficult-to-interpret waveforms. 8 simultaneous high/low voltage comparisons eliminate ambiguity.
Key Features
  • 400MHz Ultra-High-Speed Sampling: Variable sampling from 1MHz to 400MHz delivers 0.07m minimum resolution — over 7* finer than standard 100MHz pre-locators. Capture the finest waveform details for precise fault distance calculation on long cable runs.
  • 120km Maximum Test Range: Industry-leading range for power transmission and long-distance telecom cable diagnostics. Fully automatic continuous sampling ensures no transient discharge event is ever missed.
  • ARC 8-Group Multi-Pulse Technology: The exclusive Arc Reflection Method simultaneously captures and displays 8 groups of high-voltage/low-voltage comparative waveforms. Automatic distance testing with manual override for expert analysis. Dramatically reduces interpretation time on complex fault signatures.
  • 10.1-inch Industrial Touch Display: 1024*600 resolution with 280nit LED backlight — visible in direct outdoor sunlight. Full English menu supporting both touchscreen and coded push-button operation for gloved-hand use in the field.
  • 300Vpp Low-Voltage Pulse with 8 Selectable Widths: 0.15μs, 0.30μs, 0.60μs, 1.20μs, 2.4μs, 5.0μs, 7.5μs, and 10μs — precisely match the pulse width to cable length and fault type for optimal reflection clarity.
  • DC 35kV Pulse Coupler Compatible: Works with high-energy impulse generators for ARM multi-pulse testing on the toughest high-impedance faults. Built-in coupler protection ensures operator and equipment safety.
  • Massive Waveform Storage & Management: Store 8,000+ low-voltage pulse and high-voltage flashover records, plus 250+ multi-pulse waveform records. All files can be named in the field and exported via USB to PC software for archival analysis and report generation.
  • Automatic Range & Waveform Analysis: Intelligent auto-ranging sets the optimal test parameters. Built-in waveform analysis automatically calculates and displays fault distance — ideal for less experienced operators or high-volume testing environments.
  • Industrial-Grade Reliability: Embedded system with industrial integrated circuits. Built-in large-capacity lithium-ion battery for extended field operation. Compliant with GB/T 18268.1 (industrial EMC), DL/T 849.1-2019 (cable fault flash tester), and JJF1042-2020 (calibration specifications).
Technical Specifications
XHGG502A — Complete Parameters
Test Range≥120km
Minimum Resolution0.07m
Sampling Frequency1MHz~400MHz, variable
Measurement Error≤±(0.5%*L+1m)
Test Blind Area≤10m
Low Voltage Pulse300Vpp ±15%; 8 widths: 0.15/0.30/0.60/1.20/2.4/5.0/7.5/10μs
Pulse Coupler Withstand VoltageDC 35kV
Test ModesTDR (low-voltage pulse), ICE (impulse current), ARM (arc reflection multi-pulse *8)
Display10.1-inch TFT color touch, 1024*600, 280nit LED backlight
OperationTouchscreen + coded push-button; full English menu
Waveform Storage8,000+ LV/HV records; 250+ multi-pulse records; USB export to PC
Auto FunctionsAutomatic continuous sampling, auto range setting, auto waveform analysis, auto distance display
Power SupplyAC 110V~240V, 50Hz/60Hz; built-in rechargeable lithium battery
Dimensions358 * 284 * 168mm
Weight4.7kg
Operating Environment-20℃ to +65℃; ≤90% RH; 750±30mmHg
ComplianceGB/T 18268.1; DL/T 849.1-2019; JJF1042-2020; CE; ISO
Cable Types & Fault Coverage
Cable TypeSupported Faults
Power Cables (LV/MV/HV)Low-resistance, short-circuit, open-circuit, disconnection, high-resistance leakage, high-resistance flashover
High-Frequency Coaxial CablesImpedance mismatch, open-circuit, short-circuit, water ingress
Street Light & Traffic Signal CablesGround fault, series arcing, open-circuit, leakage
Buried Wires (all cross-sections & media)Full fault spectrum across copper and aluminum conductors
Telecom Local Loop CablesShort-circuit, open-circuit, water damage, high-resistance faults
Included in the Box
  • XHGG502A Cable Fault Pre-Locator (10.1-inch host)
  • Pulse Coupler (DC 35kV rated)
  • Test Lead Set (low-voltage pulse + high-voltage connection)
  • AC Power Adapter & Charger
  • USB Cable for PC Data Export
  • Rugged Transport Case
  • User Manual
Warranty & Support

12-month free warranty against manufacturing defects. Lifetime technical support and maintenance services. CE and ISO certified. Conforms to GB/T 18268.1 industrial EMC requirements, DL/T 849.1-2019 cable fault flash tester standards, and JJF1042-2020 calibration specifications.

Request a quotation or schedule a technical consultation for the XHGG502A ARC Multi-Pulse Cable Fault Pre-Locator.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
M*i
Poland Apr 29.2026
The XHGG502 tester works flawlessly for indoor building wiring jobs. It quickly located hidden cable faults inside Warsaw’s Złota 44 high-rise. Compact, precise amid tangled inter-floor wires and saves us tons of repair time.
W
Wayne Butler
United States Mar 7.2026
Absolute workhorse for our utility crew,I’ve used this cable fault tester on underground power lines across Ohio suburbs for four months straight. Last Tuesday, we located a water-soaked cable short under a residential driveway in Columbus; it pinpointed the fault within 3 feet. It blocks signal interference perfectly amid dense parallel power lines in neighborhood subdivisions. The heavy-duty shell survives bouncing around our work trucks, and the battery stays charged through full field shifts. It slashes our digging hours and never fails on emergency service calls.
B
Brian Henderson
United States Sep 18.2025
The XHDD503C is hands down the best fault locator we’ve used in Austin, Texas. It’s shockingly precise on commercial lot faults, super durable for daily field work and drastically cuts our excavation headaches. Worth every penny for our utility crew.