Complete Turnkey System — Ready to Deploy. The XHGG502A ships with everything required for professional cable fault pre-location: 10.1-inch touch embedded host, DC 35kV pulse coupler, sampler, Q-line test leads, high-voltage connection cables, ground wire, USB communication cable, power adapter, and rugged transport cases. One order. One shipment. Start testing.
The XHGG502A is a professional ARC cable fault pre-locator built around an industrial 10.1-inch touch all-in-one computer with embedded system architecture. It integrates modern electronic and computer technologies to perform signal filtering, high-speed A/D acquisition, data processing, graphic display, and waveform analysis — completing cable wave velocity, length, and fault distance measurement in a single workflow. The instrument covers the full spectrum of cable fault types: low-resistance short circuits, open circuits, disconnections, leakage high-resistance, and flashover high-resistance faults on power cables, high-frequency coaxial cables, street light cables, and buried wires of all materials, cross-sections, and dielectric media. All technical indicators comply with GB/T 18268.1, DL/T 849.1-2019, and JJF1042-2020.
What distinguishes the XHGG502A from conventional pre-locators is its proprietary eight-pulse ARC multi-pulse method. When connected to the included DC 35kV pulse coupler, the instrument fires 8 sequential pulses at the cable fault point, simultaneously displaying 8 groups of high-voltage and low-voltage comparison waveforms on the 10.1-inch screen. The system mathematically converts any high-resistance fault trace into a clean low-resistance short-circuit equivalent waveform — making interpretation virtually unambiguous and enabling automatic distance calculation that requires no expert waveform analysis skills. This technology, combined with three test modes (TDR low-voltage pulse, ICE impulse current, and ARM arc reflection multi-pulse), delivers the highest fault detection success rate and test precision available in its class.
What's Included — Complete System, No Hidden Purchases| Item | Qty | Item | Qty |
|---|---|---|---|
| Cable Fault Pre-Locator Host (10.1-inch) | 1 | Pulse Coupler (DC 35kV) | 1 |
| Single Q-Line Test Lead | 1 | Double Q-Line Test Lead | 1 |
| High-Voltage Sampler | 1 | Coupler HV Line A | 1 |
| Coupler HV Line B | 1 | Ground Wire | 1 |
| USB Communication Cable | 1 | AC Power Cable | 1 |
| Rugged Transport Cases | 2 | User Manual & Warranty Card | 1 |
No additional accessories required. No separate coupler purchase. No missing cables. Everything needed for TDR, ICE, and ARM multi-pulse testing is included in the standard shipment.
Key Capabilities| XHGG502A — Complete Turnkey System | |
|---|---|
| Display | 10.1-inch TFT touch; 1024*600; 280nit LED backlight |
| Platform | Embedded system; touch + coded button dual operation |
| Sampling Frequency | 1MHz~400MHz |
| Minimum Resolution | 0.07m |
| Test Range | ≥120km (10 presets: 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km) |
| Test Blind Zone | ≤10m |
| Measurement Error | ≤±(0.5%*L+1m) |
| Low Voltage Pulse | 300V±15%; 8 widths: 0.1/0.30/0.60/1.20/2.4/5.0/7.5/10μs |
| Pulse Coupler | DC 35kV (included); 430*380*220mm; 10kg |
| Test Methods | TDR (LV pulse) + ICE (impulse current) + ARM (8-pulse ARC) |
| Waveform Storage | 8,000+ LV/HV records; 250+ multi-pulse; USB to PC |
| Battery | 11.1V lithium; ~2hr charge; 5hr+ operation |
| Power Input | AC 110V~240V, 50Hz/60Hz |
| Protection | IP54 rugged chassis |
| Host Dimensions | 358*284*168mm |
| Host Weight | 5kg |
| Operating Conditions | -20℃~+65℃; ≤90% RH; 750±30mmHg |
| Compliance | GB/T 18268.1; DL/T 849.1-2019; JJF1042-2020; CE; ISO |
| Method | Best For | Typical Application |
|---|---|---|
| TDR — Low-Voltage Pulse | Low-resistance, short-circuit, open-circuit, disconnection faults | Routine cable maintenance, pre-splice verification, cable length & wave velocity calibration |
| ICE — Impulse Current Flashover | High-resistance leakage faults (above several hundred Ω); flashover high-impedance faults | Post-withstand-voltage-test failure analysis, aging cable diagnostic assessment |
| ARM — 8-Pulse ARC Multi-Pulse | All high-resistance faults — converts any complex trace to short-circuit equivalent | Difficult-to-interpret single-pulse results; faults on mixed-dielectric cables; multi-joint long-distance cables |
Q: Does the coupler come with the instrument?
A: Yes. The DC 35kV pulse coupler (430*380*220mm, 10kg) is included as standard in every XHGG502A shipment, along with coupler high-voltage connection cables A and B.
Q: Can it test XLPE (cross-linked polyethylene) cables?
A: Yes. The XHGG502A is suitable for all cable insulation types — XLPE, oil-impregnated paper, rubber, and PVC — across low-voltage (6kV and below), medium/high-voltage (6kV~35kV), and high-voltage (66kV+) power cables.
Q: Does the instrument work without mains power?
A: Yes. The built-in 11.1V lithium battery supports low-voltage pulse testing for open-circuit and low-resistance faults without external power. For high-voltage flashover and multi-pulse methods, connect to AC 110V~240V or a generator.
Q: Can waveforms be exported to a computer?
A: Yes. All 8,000+ stored waveforms can be exported via USB to PC software for archival management, comparative analysis, and formal report generation.
Q: Is training included?
A: Each shipment includes a comprehensive user manual. Contact us for on-site training, remote video support, or extended warranty options tailored to your team's requirements.
Request a quotation for the XHGG502A Complete Turnkey Cable Fault Pre-Locator System — One Order, Ready to Deploy.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews