Engineered for 35kV and Below — The Utility Standard. The XHGG501A2 targets the voltage range that covers 90%+ of installed power cable infrastructure: 6kV, 10kV, 11kV, 20kV, 33kV, and 35kV distribution and sub-transmission cables. 400MHz sampling, ≥68km range, ≤10m blind zone.
The XHGG501A2 ARC Cable Fault Pre-Locator is purpose-configured for the medium-voltage power cable networks that form the backbone of utility distribution systems worldwide. With a 12.1-inch industrial touch display, 400MHz real-time sampling engine, and fully automatic continuous waveform acquisition, it accurately locates low-resistance, short-circuit, open-circuit, leakage high-resistance, and flashover high-resistance faults on power cables rated 35kV and below. Three test methods — low-voltage pulse (400V, 0.25/2/4μs triple width), high-voltage flashover, and multi-pulse — ensure coverage of all fault types encountered in medium-voltage cable maintenance. The instrument also calibrates cable length and measures propagation velocity for accurate distance calculation. CE ISO certified.
![]()
![]()
High-voltage transmission cables (66kV+) are inspected by dedicated transmission-line maintenance teams with specialized equipment budgets. Low-voltage cables (<1kV) are typically short enough for section-by-section isolation testing. The medium-voltage range — 6kV to 35kV — is where the majority of cable fault investigations occur: urban distribution feeders, industrial plant incoming cables, wind farm collection circuits, and substation interconnectors. These cables run kilometers between accessible points, cross under roads and buildings, and carry loads that cannot be shed for extended troubleshooting. The XHGG501A2 is built specifically for this operating environment.
12.1-Inch Touch Display with Physical ControlsThe instrument's human interface combines a capacitive touch screen with dedicated hardware knobs — a deliberate choice for field reliability. When wearing insulated gloves in a 35kV substation, the physical amplitude and displacement knobs allow waveform adjustment without removing gloves or risking touch-screen contamination in wet conditions. The 4-grid LED battery indicator provides instant power status at a glance — no menu navigation required. USB ×2 ports support external keyboard/mouse for office-based analysis and USB flash drives for waveform export. A dedicated self-check button verifies system integrity with a single press before field deployment.
400MHz Sampling with Triple Pulse WidthThe XHGG501A2's 400MHz sampling engine acquires 400 million data points per second — translating to 0.1m reading resolution and <0.5m test accuracy. Three selectable pulse widths optimize the signal for different fault scenarios:
| Parameter | Specification |
|---|---|
| Voltage Rating | Power cables 35kV and below |
| Display | 12.1-inch industrial touch LCD; 4-grid battery LED; physical amplitude/displacement knobs |
| Sampling Frequency | 400MHz; fully automatic continuous sampling |
| Reading Resolution | 0.1m |
| Test Accuracy | <0.5m |
| Test Range | ≥68km; presets: <1km / <3km / >3km |
| Test Blind Zone | ≤10m |
| Measurement Error | ≤±(0.5%×L+1m), L = cable length |
| Pulse Amplitude | 400V |
| Pulse Width | 0.25μs / 2μs / 4μs |
| Test Methods | Low-voltage pulse / High-voltage flashover / Multi-pulse |
| Connectivity | USB ×2; external keyboard/mouse support |
| Self-Diagnostics | Built-in self-check function |
| Battery | 10400mAH lithium; AC 110V~240V, 50Hz/60Hz charging |
| Dimensions | 430 × 380 × 220mm |
| Weight | 10kg |
| Operating Conditions | -20℃~+65℃; ≤90% RH; 750±30mmHg |
| Compliance | CE, ISO |
| Application | Typical Cables |
|---|---|
| Urban Distribution Networks | 10kV, 11kV, 20kV XLPE underground feeders; PILC legacy cables |
| Industrial Plant Incoming Supply | 33kV, 35kV factory incoming cables; substation interconnectors |
| Renewable Energy Collection | 33kV wind farm collector circuits; solar farm medium-voltage networks |
| Cable Length Calibration | Precise length measurement for cable inventory and project acceptance |
| Pre-Commissioning Testing | New cable installation verification before energization |
Request a quotation for the XHGG501A2 — specify your voltage levels and cable types for application-specific guidance.