logo
Home > Products >
Cable Fault Locator
>
35kv Power Cable Fault Detector with Outer Sleeve Failure and Rough Measurement Capabilities

35kv Power Cable Fault Detector with Outer Sleeve Failure and Rough Measurement Capabilities

Product Details:
Place of Origin: Xi'an
Brand Name: XZH TEST
Certification: CE
Model Number: XHHG521A
Detail Information
Place of Origin:
Xi'an
Brand Name:
XZH TEST
Certification:
CE
Model Number:
XHHG521A
Highlight:

High Light

Highlight:

Outer sleeve failure Cable Fault Locator

,

Rough measurement Power Cable Fault Detector

,

35kv Test Equipment

Trading Information
Minimum Order Quantity:
1set
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
3000unit/year
Product Description
Power Cable Fault Locator
Professional test equipment designed for detecting outer sleeve failures and performing rough measurements in power cable systems.

The cable outer sheath fault tester is designed based on the Murray bridge principle and can be used to locate the breakdown points of various wires and cables, as well as defects that are not broken down but have low insulation resistance values.

Specialized for power cable fault detection
Identifies outer sleeve failures efficiently
Provides rough measurement capabilities
Essential equipment for cable maintenance

Technical parameters

Open-circuit voltage  ≥7500V
Short-circuit current  ≥100mA (when adjusting balance, it is recommended to set it to 5~40mA)
Positioning ratio  accuracy ±(0.2%·L±1) meters
Operating power supply AC 220V (±10%), 50Hz±1Hz; 8.4V built-in battery

35kv Power Cable Fault Detector with Outer Sleeve Failure and Rough Measurement Capabilities

35kv Power Cable Fault Detector with Outer Sleeve Failure and Rough Measurement Capabilities

35kv Power Cable Fault Detector with Outer Sleeve Failure and Rough Measurement Capabilities

Ratings & Review

Overall Rating

4.5
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
50%
4 stars
50%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

T
Todd Richardson
United States Sep 2.2026
I’ve been running the XHZS506YS out in Phoenix, AZ. One of our guys nearly got burned bad because he didn’t verify if the buried cable was energized. This thing’s live‑voltage alert saved us from a serious safety incident. Fault pinpointing is quick, holds up great in the brutal desert heat. Keeps our crew protected and slashes troubleshooting time. Absolute must‑have tool for every field tech on our team.
Γ
Γιώργος Κωνσταντίνου
Greece Jul 15.2026
Ο εντοπιστής σφαλμάτων XHDD503C+ δουλεύει πολύ καλά για την ιδιωτική μας ομάδα. Βρήκαμε γρήγορα βλάβη σε υπόγειο καλώδιο στη Θεσσαλονίκη. Έχει μεγάλη ακρίβεια, αντέχει τις δύσκολες συνθήκες στο πεδίο και μας μείωσε πολύ τις εκσκαφές. Το προτείνω ανεπιφύλακτα!