logo
Home > Products >
Cable Fault Locator
>
Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

Product Details:
Place of Origin: Xi'an Shaanxi China
Brand Name: XZH TEST
Certification: ISO CE
Model Number: XHHG520
Detail Information
Place of Origin:
Xi'an Shaanxi China
Brand Name:
XZH TEST
Certification:
ISO CE
Model Number:
XHHG520
Highlight:

High Light

Highlight:

Adjustable ≥15kV Cable Fault Locator

,

Outer sleeve failure Cable Fault Detector

,

TDR Cable Tester

Trading Information
Minimum Order Quantity:
1set
Packaging Details:
wooden packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
3000unit/year
Product Description
XHHG520
Professional-grade cable fault locator designed for detecting and locating outer sleeve failures in high-voltage cables.
The cable outer sheath fault tester is designed based on the Murray bridge principle and can be used to locate breakdown points and defects in various wires and cables that are not broken down but have low insulation resistance values.
Features
Adjustable voltage output ≥15kV
Specialized for outer sleeve failure detection
Precision locating capabilities
Adjustable output voltage;
High accuracy and stability;
 Employs a high-sensitivity amplifier and galvanometer for balance indication;
Zero-point protection;
Automatic fault point detection, while retaining manual testing functionality;
Key Specification Value
Voltage Range ≥15kV (adjustable)
Primary Application Outer sleeve failure detection

Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

The cable outer sheath fault tester is particularly suitable for:

1. High-resistance breakdown points in cables after installation, especially linear high-resistance breakdown points that are difficult to burn into low-resistance conditions, such as linear high-resistance breakdowns at cable joints.

2. Flashover-type breakdown points, where the constant current source can maintain the arc after breakdown, a stable current flows through the bridge, and the bridge has sufficient sensitivity.

3. Defects that have not yet broken down but have low resistance, such as insulation defects where a megohmmeter reveals a low cable resistance value, but the cable does not break down under operating voltage.

Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

Ratings & Review

Overall Rating

4.5
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
50%
4 stars
50%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

T
Todd Richardson
United States Sep 2.2026
I’ve been running the XHZS506YS out in Phoenix, AZ. One of our guys nearly got burned bad because he didn’t verify if the buried cable was energized. This thing’s live‑voltage alert saved us from a serious safety incident. Fault pinpointing is quick, holds up great in the brutal desert heat. Keeps our crew protected and slashes troubleshooting time. Absolute must‑have tool for every field tech on our team.
Γ
Γιώργος Κωνσταντίνου
Greece Jul 15.2026
Ο εντοπιστής σφαλμάτων XHDD503C+ δουλεύει πολύ καλά για την ιδιωτική μας ομάδα. Βρήκαμε γρήγορα βλάβη σε υπόγειο καλώδιο στη Θεσσαλονίκη. Έχει μεγάλη ακρίβεια, αντέχει τις δύσκολες συνθήκες στο πεδίο και μας μείωσε πολύ τις εκσκαφές. Το προτείνω ανεπιφύλακτα!