Power Ground Resistance Tester XHDJ706 30k Ohm Soil Resistivity 4 Wire

Power Ground Resistance Tester XHDJ706 30k Ohm Soil Resistivity 4 Wire

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHDJ706
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHDJ706
Model NO.:
XHDJ706
Power:
Electricity
Customized:
Customized
Color:
Black
Origin:
China
Supply Ability:
2000PCS/Year
Customization:
Available
After-sales Service:
Warranty Certificate
Warranty:
12 Months
Highlight:

High Light

Highlight:

ground resistance tester for soil

,

electricity tester for voltage testing

,

XHDJ706 ground resistivity tester

Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
5-8 days
Payment Terms:
T/T
Supply Ability:
2000 PCS/Year
Product Description
XHDJ706 · EARTH RESISTANCE & SOIL RESISTIVITY
Power Ground Resistance Tester XHDJ706 30k Ohm Soil Resistivity 4 Wire
Tower & distribution
0.00 Ω – 30 kΩ
128 Hz test
500 data sets

The XHDJ706 is a digital earth resistance and soil resistivity tester for power-system grounding checks. It covers ground resistance from 0.00 Ω to 30.00 kΩ, soil resistivity from 0.00 Ωm to 9999 kΩm, and ground voltage from 0.00 V to 600 V AC.

For tower and distribution grounding, the four-wire connection separates the voltage and current circuits and removes the effect of contact resistance and test-lead resistance. The meter also checks the connection status of each interface and the interference voltage and frequency of the ground network before the reading is taken.

Product View
Ground Resistance Tester Earth Test Soil Resistivity Ground Voltage Tester (XHDJ706)
Ground Resistance Tester Earth Test Soil Resistivity Ground Voltage Tester (XHDJ706)
Who This Tester Is For

For power transmission and distribution field crews who test grounding at towers, substations and distribution equipment.

Transmission-line crews checking tower footings and overhead-line grounding before return to service.
Power distribution teams testing pole grounds and distribution equipment grounds, including grounding systems with multiple independent earth points.
Tower-line teams checking tower grounding and overhead-line grounding along transmission and distribution routes.
The four-wire method uses the ES auxiliary ground clamped to the same point as E, which removes contact resistance and test-lead resistance from the reading. Three-wire and simple two-wire methods are also provided.
Key Capabilities
Four-wire ground resistance measurement for tower and distribution grounding, with three-wire and simple two-wire modes for confined sites.
Ground resistance 0.00 Ω – 30.00 kΩ with automatic range shift; 0.01 Ω resolution in the lowest range.
Soil resistivity using the four-pole Wenner method, with electrode spacing settable from 1 m to 100 m.
128 Hz test frequency, AC short-circuit current above 20 mA and open-circuit voltage up to AC 28 V.
Automatically detects interface connection, interference voltage and interference frequency; readings should be taken with interference voltage below 20 V and interference current below 2 A.
Ground voltage measurement from AC 0.00 V to 600 V; this function is for ground voltage, not commercial AC supply measurement.
500-group data storage, on-meter review and deletion, and an alarm for values above the set limit.
Four-digit LCD with backlight, 111 mm × 68 mm display, and APO auto power-off after 15 minutes.
Measuring Range and Accuracy
RangeAccuracyResolution
Ground resistance (R)0.00 Ω – 30.00 Ω±2 % rdg ± 5 dgt0.01 Ω
Ground resistance (R)30.0 Ω – 300.0 Ω±2 % rdg ± 3 dgt0.1 Ω
Ground resistance (R)300 Ω – 3000 Ω±2 % rdg ± 3 dgt1 Ω
Ground resistance (R)3.00 kΩ – 30.00 kΩ±2 % rdg ± 3 dgt10 Ω
Soil resistivity (ρ)0.00 Ωm – 99.99 Ωmρ = 2πaR0.01 Ωm
Soil resistivity (ρ)100.0 Ωm – 999.9 Ωmρ = 2πaR0.1 Ωm
Soil resistivity (ρ)1000 Ωm – 9999 Ωmρ = 2πaR1 Ωm
Soil resistivity (ρ)10.00 kΩm – 99.99 kΩmρ = 2πaR10 Ωm
Soil resistivity (ρ)100.0 kΩm – 999.9 kΩmρ = 2πaR100 Ωm
Soil resistivity (ρ)1000 kΩm – 9999 kΩmρ = 2πaR1 kΩm
Ground voltageAC 0.00 V – 600 V±2 % rdg ± 3 dgt0.01 V
Technical Specifications
ParameterSpecification
FunctionTwo-wire, three-wire and four-wire ground resistance; soil resistivity; ground voltage
Ground resistance range0.00 Ω – 30.00 kΩ, automatic range shift
Soil resistivity range0.00 Ωm – 9999 kΩm, automatic range shift
Ground voltage rangeAC 0.00 V – 600 V
Measurement methodGround resistance: rated current change-pole method; soil resistivity: four-pole Wenner method; ground voltage: average rectification
Test frequency128 Hz
Short-circuit test currentAC > 20 mA, sine wave
Open-circuit test voltageAC 28 V max
Electrode spacing1 m – 100 m, settable
Display4-digit large LCD, 111 mm × 68 mm; display field 108 mm × 65 mm; off-white backlight
Data storage500 groups; MEM storage indication; FULL symbol when full
Power supply6 × 1.5 V LR14 alkaline batteries (9 V); continuous standby > 100 hours
Automatic shut-downAPO indication; auto power-off after 15 minutes
Dimensions240 mm (L) × 188 mm (W) × 85 mm (H)
WeightInstrument 1280 g including battery; test line 1300 g; auxiliary ground rods 720 g (4 pieces)
Operating conditions-10 °C – 40 °C; < 80 % RH
Storage conditions-20 °C – 60 °C; < 70 % RH
Overload protectionGround resistance: AC 280 V / 3 s between H-E and S-ES ports
Insulation resistance≥ 20 MΩ at 500 V between circuit and case
Withstand voltageAC 3700 V/rms between circuit and case
StandardsIEC61010-1 (CAT III 300 V, CAT IV 150 V, pollution degree 2); IEC61010-031; IEC61557-1; IEC61557-5; JJG 366-2004; IEC61326 (EMC)
Frequently Asked Questions
Q1.Can the XHDJ706 be used for tower and substation grounding?
Yes. It is suitable for tower transmission lines, power distribution lines and factory grounding grids. Four-wire measurement is used for precision work, with three-wire and simple two-wire modes available for other site conditions.
Q2.How does the meter deal with interference at a power site?
It automatically detects the connection status of each interface and the interference voltage and frequency of the ground network. Measurement should avoid interference voltage above 20 V and interference current above 2 A.
Q3.What test frequency and current does it use?
The test frequency is 128 Hz. Short-circuit test current is AC above 20 mA as a sine wave, and open-circuit test voltage is AC 28 V maximum.
Q4.What accuracy is specified for low ground resistance?
For 0.00 Ω – 30.00 Ω the accuracy is ±2 % rdg ± 5 dgt with 0.01 Ω resolution. Higher ranges use ±2 % rdg ± 3 dgt with 0.1 Ω, 1 Ω or 10 Ω resolution.
Q5.What are the operating and storage conditions?
Operating: -10 °C to 40 °C at below 80 % RH. Storage: -20 °C to 60 °C at below 70 % RH. The meter uses 6 × 1.5 V LR14 alkaline batteries and has more than 100 hours of continuous standby.
Grounding test check
Send the grounding system type, test range and site conditions, and we will confirm the XHDJ706 configuration and accessories.