logo
Home > Products >
Cable Fault Locator
>
10kv DC Hipot Test Step Voltage Method Cable Outer Sheath Fault Locator

10kv DC Hipot Test Step Voltage Method Cable Outer Sheath Fault Locator

Product Details:
Place of Origin: China
Brand Name: XZH TEST
Certification: CE ISO
Model Number: XHHD523L
Detail Information
Place of Origin:
China
Brand Name:
XZH TEST
Certification:
CE ISO
Model Number:
XHHD523L
Product Name:
HV Cable Sheath Fault Locator
Color:
Black
Display:
Digit Display
Accuracy:
±0.01%-0.03%
Material:
Aluminum Alloy
Operating Temperature:
-20-60.C
Highlight:

High Light

Highlight:

Cable Fault Locator for Construction Companies

,

110kV Cable Fault Locator

,

Cable Fault Locator for Design Institutes

Trading Information
Minimum Order Quantity:
1
Packaging Details:
Wooden Packing
Delivery Time:
7 WORK DAYS
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description

XHHD523L


With the city network development, many power bureau, construction, and even the design institute are first met 110kV XLPE cable, due to time and lack of experience, resulting in many cable outer sheath can’t passed withstand voltage test (10kV/1min). At present, the external protective layer mostly uses HDPE sheath material, passed the DC 25kV/5min withstand voltage test before out of factory, the leakage current is less than dozens of µA. Therefore, after the laying of defects mostly by laying, including external damage during filling and covering process. The defects include termite bites; ground box with water; deterioration of the original defects; grounding wire or part moisture penetration insulation resistance decreased and other reasons, sometimes because the cable buried too deep, or the complexity of the situation around buried cable, so that the positioning is very difficult, some defects can’t be solved after many years, with the hidden danger to run.


Function

Power  220V(1±10%)50Hz(1±5%)
Output voltage 0~10kV(Square wave)
output current 200mA
Output capacity 2kVA
Frequency adjust Min:0.4Hz,Max:1Hz(range adjustable)
Weight 32kg



Features

1.Voltage adjustable.

2.Frequency adjustable.
3.Over current protection.
4.Pin-pointing and withstand testing switched by one button, non-blind area. The receiver sensitivity can be adjusted.
5.Signal frequency adjustable, and zero protection.
6.The test range without blind area
7.The receiver sensitivity is adjustable
8.Signal frequency is adjustable

Product Description

10kv DC Hipot Test Step Voltage Method Cable Outer Sheath Fault Locator 0

10kv DC Hipot Test Step Voltage Method Cable Outer Sheath Fault Locator 110kv DC Hipot Test Step Voltage Method Cable Outer Sheath Fault Locator 2