logo
Home > Products >
Cable Fault Locator
>
Trolley High Voltage Surge Generator 2048J 32kV Cable Fault Thumper with DC Withstand Test| XHHV535-4TS

Trolley High Voltage Surge Generator 2048J 32kV Cable Fault Thumper with DC Withstand Test| XHHV535-4TS

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: CE, ISO
Model Number: XHHV535-4TS
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE, ISO
Model Number:
XHHV535-4TS
Impulse Voltage:
0~8kV / 0~16kV / 0~32kV Three-stage Adjustable
DC Withstand Test:
Supported, Up To 32kV
Built-in Capacitor:
4μF/32kV, 16μF/16kV, 64μF/8kV
Discharge Energy:
2048J @ Each Voltage Level
High Voltage Accuracy:
Class 1.5
Surge Power:
2KVA
Discharge Modes:
Timing Auto / Manual Single / DC Withstand
Overcurrent Protection:
8mA (3-second Threshold)
Working Power:
AC 220V±10%, 50Hz/60Hz
Dimensions:
534×444×805mm
Weight:
118kg (trolley)
Ambient Temperature:
-20℃~+50℃
Highlight:

High Light

Highlight:

High Voltage Surge Generator 2048J

,

Cable Fault Thumper 32kV

,

High Voltage DC Withstand Test

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
Wooden case with foam padding
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
2000 units per year
Product Description

 Trolley High Voltage Surge Generator with DC Withstand Test  XHHV535-4TS

The XHHV535-4TS is an integrated trolley-type high voltage test instrument combining a DC high-voltage source, energy storage capacitor bank, discharge ball gap, and automatic discharge safety system. Engineered for underground cable fault testing up to 35kV, it delivers precision impulse discharge with 2048J energy and built-in DC withstand voltage testing capability.

Key Features

  • DC Withstand Voltage Test: Integrated DC high-voltage output mode for cable insulation withstand testing, eliminating the need for separate equipment
  • Three-Stage Capacitor Bank: 4μF/32kV, 16μF/16kV, 64μF/8kV – automatically matched to voltage selection for optimal discharge characteristics
  • Class 1.5 Precision: High-accuracy voltage divider provides real-time kV readings on the high-voltage side during both impulse and DC operations
  • Dual-Mode Discharge: Timing auto-discharge (~7s interval) for continuous fault pinpointing, plus manual single-shot mode for precise distance measurement
  • Auto Safety Discharge: Internal discharge circuit automatically drains capacitor residual voltage when stopped, displayed on panel voltmeter
  • Overcurrent Protection: 8mA threshold with 3-second delay, preventing equipment damage from sustained faults
  • Zero-Start Interlock: Voltage adjustment knob must return to zero before startup; prevents accidental high-voltage output
  • Emergency Stop: Dedicated emergency stop button immediately cuts high-voltage output and activates internal discharge

Technical Specifications

Impulse Voltage Range 0~8kV / 0~16kV / 0~32kV (adjustable)
DC Withstand Voltage Up to 32kV
Built-in Capacitor 4μF @ 32kV / 16μF @ 16kV / 64μF @ 8kV
Discharge Energy 2048J (consistent across all voltage levels)
Voltage Accuracy Class 1.5
Surge Power 2KVA
Impact Interval ~7 seconds automatic / manual single-shot
Overcurrent Protection 8mA (3-second threshold)
Over-temperature Protection 65°C
Working Power Supply AC 220V±10%, 50Hz/60Hz
Ambient Temperature -20℃~+50℃
Dimensions (L*W*H) 534*444*805mm
Weight Approx. 118kg

Applications

Suitable for power utilities, cable testing contractors, and industrial electrical maintenance teams performing underground cable fault location, cable thumping, and DC withstand voltage testing on distribution networks rated 35kV and below. Compatible with TDR cable fault pre-locators and acoustic-magnetic pinpointers for complete cable fault location systems.

Request a quotation or technical datasheet for the XHHV535-4TS today.

▎Frequently Asked Questions

Q: How does a high voltage surge generator work in cable fault detection?

The surge generator discharges a high-energy pulse into the faulty cable, creating a controlled high-voltage arc at the fault point. This arc produces both an acoustic signal (loud thumping sound detectable by ground microphones) and an electromagnetic pulse (detectable by an inductive receiver). By combining acoustic and electromagnetic signal arrival times, operators can pinpoint the exact fault location with precision—a technique known as acoustic-magnetic synchronization.

Q: Which voltage range should I select for different cable types?

Voltage selection follows the cable's rated operating voltage as a general guideline. For low-voltage cables (up to 1kV), use the 8kV or 12kV range. For medium-voltage distribution cables (6-15kV), the 16kV range is appropriate. For high-voltage transmission cables (35kV and above), use the 32kV range. Always consult the cable manufacturer's maximum test voltage specifications and ensure all safety clearances are maintained during high-voltage operation.

Q: What safety precautions must be observed during surge generator operation?

High voltage surge generator testing requires strict safety protocols. Always verify the cable is fully de-energized and isolated from all power sources before connection. Establish a minimum 5-meter safety perimeter around the test zone with warning signs. All personnel must wear appropriate PPE including arc-rated clothing, HV insulating gloves, and dielectric overshoes. The integrated safety features—automatic discharge upon power-off, emergency stop, and zero-voltage interlock—provide additional layers of protection but should never replace proper safety procedures.

Q: What is the advantage of multiple energy levels (Joules) on this unit?

Different energy levels serve different diagnostic purposes. Low energy settings (e.g., 864J–1024J) are ideal for initial fault confirmation and locating high-resistance faults where excessive energy could worsen cable damage. Medium energy (1225J–2048J) provides optimal acoustic signal strength for most routine fault pinpointing. High energy (2450J+) is reserved for very long cables, deep burial scenarios, or high-impedance faults that require stronger arc generation to produce a detectable acoustic signature. The three-level selection allows operators to match energy output to field conditions.

Q: What warranty and support is included with this surge generator?

12-month standard warranty against manufacturing defects with lifetime technical support. CE and ISO 9001:2015 certified. Each unit includes the surge generator, HV output cable, ground cable, discharge rod, user manual, and a heavy-duty trolley with locking casters for safe transport. On-site installation, commissioning, and operator safety training are available upon request. Spare parts including discharge gaps, capacitors, and HV diodes are stocked for rapid replacement.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

J
John Miller
United States Mar 26.2026
We tested the XHHV535-4Z on several underground cable repair jobs in Houston. It helped our team locate faults faster and reduced unnecessary excavation. The equipment is powerful, stable, and easy to operate in the field. A great solution for utility and industrial cable maintenance.
L
Lee
Malaysia Jan 10.2024
Our customized service is incredibly thoughtful: our R&D team can accurately address specific needs, providing tailored solutions for everything from voltage and frequency to environmental adaptation. They quickly provided a perfect solution for the non-standard requirements of our project, truly delivering a bespoke service.