logo
Home > Products >
Cable Fault Locator
>
35kV Underground Power Cable Fault Location System Kit (4-in-1 Integrated Test System)

35kV Underground Power Cable Fault Location System Kit (4-in-1 Integrated Test System)

Product Details:
Place of Origin: Shaanxi, China
Brand Name: XZH TEST
Certification: CE, ISO 9001, ISO 14001, ISO 45001
Model Number: XHGG502A+ / XHDD503E+ / XHGX507C1 / XHHV535-4TS+
Detail Information
Place of Origin:
Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE, ISO 9001, ISO 14001, ISO 45001
Model Number:
XHGG502A+ / XHDD503E+ / XHGX507C1 / XHHV535-4TS+
System Configuration:
4-in-1 Integrated Kit
Voltage Coverage:
0-35kV
Surge Energy:
2048J Constant Across 32kV / 16kV / 8kV
Pre-Locator Method:
TDR + 8-pulse Arc Reflection (SIM/MIM)
Pinpointing Accuracy:
0.1m Or Better
Route Tracing Frequencies:
11 Active Frequencies 640Hz-197kHz
Display:
10.1 Inch + 5.0 Inch Touchscreens
Battery Life:
5-8 Hours Continuous
Protection Class:
IP54 To IP65
Warranty:
12 Months With Lifetime Technical Support
Highlight:

High Light

Highlight:

35kV cable fault location system

,

4-in-1 integrated cable test kit

,

portable underground cable fault locator

Trading Information
Minimum Order Quantity:
1 Set
Price:
USD 12,000-18,000 / Set
Packaging Details:
Wooden case export packing with shock-proof foam, four units packed separately with accessories
Delivery Time:
15-25 working days after deposit
Payment Terms:
T/T,L/C,Western Union
Supply Ability:
30 Sets per Month
Product Description

XZH TEST 35kV underground power cable fault location system kit is a four-in-one field package that puts cable route tracing, distance pre-location, high voltage surge breakdown and acoustic-magnetic pinpointing into one matched set of instruments. The kit is assembled around the XHGG502A+ multi-pulse TDR pre-locator, the XHDD503E+ digital acoustic-magnetic pinpointer, the XHGX507C1 multi-frequency pipe and cable locator, and the XHHV535-4TS+ integrated trolley surge generator. All four units share a single impedance and timing design, so a fault on a 0-35kV XLPE or oil-paper cable can be traced, ranged, discharged and pinpointed in one working session instead of four separate mobilisations.

Key Features
  • 0-35kV Full Voltage Coverage: one kit serves 11kV, 22kV and 33kV distribution feeders as well as 35kV transmission cables, low voltage street lighting circuits and mixed oil-paper networks, so a single purchase replaces three separate test packages.
  • Eight-Pulse Arc Reflection Pre-Location: the XHGG502A+ samples from 1MHz to 400MHz and applies SIM and MIM multiple pulse methods, producing a clean reflection waveform without cosine oscillation on heavily damped or branched cables.
  • Constant 2048 Joule Surge Output: the XHHV535-4TS+ delivers 0-32kV, 0-16kV and 0-8kV with matched 4uF, 16uF and 64uF capacitance, holding energy constant across all three ranges so breakdown behaviour does not change when the voltage gear is switched.
  • Sub-Decimetre Pinpointing: the XHDD503E+ calculates the acoustic-magnetic time difference with BNR background noise reduction, reaching a stated accuracy of 0.1m or better even beside motorways, rail tracks and substation switchyards.
  • Live Cable Identification: the XHGX507C1 transmitter runs 11 active frequencies from 640Hz to 197kHz and 9 output gears, while the 200mm flexible Rogowski clamp stores up to 20 cable signatures for unambiguous dead or live identification.
  • Industrial Safety Chain: zero-start interlock, automatic capacitor discharge, earth loop monitoring and a dual class-2.5 analogue meter chain protect the operator through every discharge cycle, with IP54 to IP65 protection on the field units.
Four-in-One System Architecture
  • Unit 1 - XHGG502A+ Cable Fault Pre-Locator: 10.1 inch TFT touchscreen, 1MHz-400MHz sampling, TDR plus 8-times multiple pulse arc reflection, range of 150km or more, blind zone of 10m or less, resolution 0.07m, memory for more than 8000 waveforms.
  • Unit 2 - XHDD503E+ Acoustic-Magnetic Pinpointer: 5.0 inch touchscreen, acoustic-magnetic time difference calculation, BNR noise reduction, step voltage A-frame mode, pinpointing accuracy of 0.1m or better, IP65 multi-layer shielded vibration sensor.
  • Unit 3 - XHGX507C1 Pipe and Cable Locator: 15W transmitter with 9 gears and 11 frequencies, 3D receiver with 360 degree cruise navigation, direct connection range up to 20km, depth measurement 0 to 20m at plus or minus 5 percent.
  • Unit 4 - XHHV535-4TS+ Trolley Surge Generator: 0-32kV, 0-16kV and 0-8kV output at a constant 2048 joules, 3s, 6s, 9s and manual discharge modes, dual class-2.5 meters, zero-start interlock and earth ground monitor.
Four-Step Field Workflow
  1. Route tracing and identification: the XHGX507C1 confirms cable path and bury depth, then the Rogowski clamp tags the exact target cable among parallel runs.
  2. Diagnosis and pre-location: the XHGG502A+ applies TDR for low resistance faults and 8-pulse arc reflection for high resistance and flashing faults, returning a distance reading in metres.
  3. High voltage breakdown: the XHHV535-4TS+ applies periodic 32kV, 2048 joule pulses until the fault arc flashes over at the defect point.
  4. Millimetre pinpointing: the XHDD503E+ locks the acoustic and electromagnetic signals and converts the time difference into a spot on the ground, accurate to 0.1m.
Technical Specifications
ParameterXHGG502A+ Pre-LocatorXHDD503E+ PinpointerXHGX507C1 Path LocatorXHHV535-4TS+ Surge Generator
Primary FunctionDistance pre-location by TDR and SIMAcoustic-magnetic pinpointingRoute, depth and cable identificationHigh voltage surge breakdown
Output or RangeLow voltage pulse 300V plus or minus 15 percentDetection range 75mV to 75VTransmitter output up to 300V0-32kV, 0-16kV, 0-8kV in three gears
Energy or PowerBuilt-in lithium 11.1V, over 5 hoursBuilt-in lithium ion, over 8 hours15W maximum, 9 adjustable levelsConstant 2048 joules on all three ranges
Test Range or DepthRange 150km or more, blind zone 10m or lessPinpointing accuracy 0.1m or betterDirect 0-20km, depth 0-20m plus or minus 5 percentRated for cables up to 35kV
Display10.1 inch touchscreen, 1024x6005.0 inch touchscreen, 480x8504.3 inch receiver and 5.0 inch transmitterDual class-2.5 analogue meters
Safety ProtectionHigh voltage pulse coupler isolationBNR noise mute, IP65 probeOverload and short circuit protectionZero-start, ground detect, auto discharge
Field EnclosureIP54 ABS carry caseIP65 shielded sensor headIP65 receiver and transmitterIP54 trolley frame with HV cage
Operating Temperature-10 to 50 degrees Celsius-10 to 50 degrees Celsius-10 to 55 degrees Celsius-10 to 45 degrees Celsius
Packing List and Accessories
  • Unit 1 package: XHGG502A+ host, DC 35kV pulse coupler, single and double Q cables, current sampler, ground wire, fast charger, operating manual.
  • Unit 2 package: XHDD503E+ host, vibration ground probe with rod, noise isolating headphones, A-frame with needles, charger, transport case.
  • Unit 3 package: 15W transmitter, 3D receiver, transmitting caliper 125mm, flexible Rogowski clamp 200mm, test leads, ground spike.
  • Unit 4 package: XHHV535-4TS+ trolley host at 32kV and 2048 joules, shielded HV output cable, earth cable, discharge rod, calibration report and manual.
Applications and Standards

The kit is used by national grid and power utility crews, wind and solar farms, petrochemical and steel plants, mining grids, rail corridors and airport airfield lighting networks. Typical jobs include acceptance testing of newly laid 33kV feeders, emergency repair of storm damaged cable sections, locating sheath and joint defects before excavation, and identifying target cables in dense urban duct banks.

Equipment design follows DL/T 849, DL/T 846, GB/T 18268.1 and IEC 61010-1 with CAT III 600V rating. The factory operates under ISO 9001, ISO 14001 and ISO 45001, and every unit is CE marked and burn-in tested for 72 hours before shipment.

Technical FAQ

Q1: Can one kit really cover 11kV, 22kV and 33kV cables?
The surge generator reaches 32kV and 2048 joules, which is the industry reference level for 35kV class cable breakdown. The pre-locator and pinpointer are voltage independent, so the same kit covers 11kV, 22kV, 33kV and 35kV work without extra hardware.

Q2: Why eight pulses instead of a single pulse?
On branched, water logged or long cables a single pulse produces a reflection buried in noise. Eight-pulse arc reflection averages repeated shots, removes cosine oscillation and exposes the fault reflection even when the fault resistance is high.

Q3: How accurate is the pinpointing step in practice?
The XHDD503E+ combines acoustic and electromagnetic channels and calculates the time difference between them, which cancels the effect of sound speed variation in different soils. Field accuracy is 0.1m or better under normal surface conditions.

Q4: Does the kit need a separate power source on site?
No. All four units run on built-in lithium batteries with 5 to 8 hours of continuous work, and the trolley generator is charged from mains or a vehicle inverter between jobs.

Q5: What support is provided after delivery?
Every kit carries a 12 month warranty, lifetime technical support, remote commissioning guidance and a factory calibration report traceable to national standards.

Buyer Guide

Integrated kit or separate instruments? Separate units bought over time rarely match in impedance and timing, and mismatch shows up as ghost reflections in multiple pulse testing. A factory matched kit removes that risk and gives single source warranty coverage.

What should a tender specification include? Require at least 2048 joules at 32kV, eight-pulse arc reflection, acoustic-magnetic synchronisation with time difference calculation, 11 frequency route tracing, and a calibration certificate for each unit.

How is shipping and training handled? Kits ship in wooden case export packing within 15 to 25 days, and remote or on-site commissioning training can be arranged with the order.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

S
Saif Al Hammadi
United Arab Emirates Jun 17.2026
This full‑set cable fault testing system (XHHV535‑4TS, XHGG502A, XHDD503C, XHGX507C) performs brilliantly for our DEWA government team. It quickly located underground cable faults at Al Sheraa headquarters in Al Jaddaf, Dubai. Stable under high heat and sandy conditions, the combined modules deliver precise readings, drastically cutting troubleshooting time. Reliable all‑in‑one solution for urban utility maintenance.