XZH TEST 35kV underground power cable fault location system kit is a four-in-one field package that puts cable route tracing, distance pre-location, high voltage surge breakdown and acoustic-magnetic pinpointing into one matched set of instruments. The kit is assembled around the XHGG502A+ multi-pulse TDR pre-locator, the XHDD503E+ digital acoustic-magnetic pinpointer, the XHGX507C1 multi-frequency pipe and cable locator, and the XHHV535-4TS+ integrated trolley surge generator. All four units share a single impedance and timing design, so a fault on a 0-35kV XLPE or oil-paper cable can be traced, ranged, discharged and pinpointed in one working session instead of four separate mobilisations.
Key Features| Parameter | XHGG502A+ Pre-Locator | XHDD503E+ Pinpointer | XHGX507C1 Path Locator | XHHV535-4TS+ Surge Generator |
|---|---|---|---|---|
| Primary Function | Distance pre-location by TDR and SIM | Acoustic-magnetic pinpointing | Route, depth and cable identification | High voltage surge breakdown |
| Output or Range | Low voltage pulse 300V plus or minus 15 percent | Detection range 75mV to 75V | Transmitter output up to 300V | 0-32kV, 0-16kV, 0-8kV in three gears |
| Energy or Power | Built-in lithium 11.1V, over 5 hours | Built-in lithium ion, over 8 hours | 15W maximum, 9 adjustable levels | Constant 2048 joules on all three ranges |
| Test Range or Depth | Range 150km or more, blind zone 10m or less | Pinpointing accuracy 0.1m or better | Direct 0-20km, depth 0-20m plus or minus 5 percent | Rated for cables up to 35kV |
| Display | 10.1 inch touchscreen, 1024x600 | 5.0 inch touchscreen, 480x850 | 4.3 inch receiver and 5.0 inch transmitter | Dual class-2.5 analogue meters |
| Safety Protection | High voltage pulse coupler isolation | BNR noise mute, IP65 probe | Overload and short circuit protection | Zero-start, ground detect, auto discharge |
| Field Enclosure | IP54 ABS carry case | IP65 shielded sensor head | IP65 receiver and transmitter | IP54 trolley frame with HV cage |
| Operating Temperature | -10 to 50 degrees Celsius | -10 to 50 degrees Celsius | -10 to 55 degrees Celsius | -10 to 45 degrees Celsius |
The kit is used by national grid and power utility crews, wind and solar farms, petrochemical and steel plants, mining grids, rail corridors and airport airfield lighting networks. Typical jobs include acceptance testing of newly laid 33kV feeders, emergency repair of storm damaged cable sections, locating sheath and joint defects before excavation, and identifying target cables in dense urban duct banks.
Equipment design follows DL/T 849, DL/T 846, GB/T 18268.1 and IEC 61010-1 with CAT III 600V rating. The factory operates under ISO 9001, ISO 14001 and ISO 45001, and every unit is CE marked and burn-in tested for 72 hours before shipment.
Technical FAQQ1: Can one kit really cover 11kV, 22kV and 33kV cables?
The surge generator reaches 32kV and 2048 joules, which is the industry reference level for 35kV class cable breakdown. The pre-locator and pinpointer are voltage independent, so the same kit covers 11kV, 22kV, 33kV and 35kV work without extra hardware.
Q2: Why eight pulses instead of a single pulse?
On branched, water logged or long cables a single pulse produces a reflection buried in noise. Eight-pulse arc reflection averages repeated shots, removes cosine oscillation and exposes the fault reflection even when the fault resistance is high.
Q3: How accurate is the pinpointing step in practice?
The XHDD503E+ combines acoustic and electromagnetic channels and calculates the time difference between them, which cancels the effect of sound speed variation in different soils. Field accuracy is 0.1m or better under normal surface conditions.
Q4: Does the kit need a separate power source on site?
No. All four units run on built-in lithium batteries with 5 to 8 hours of continuous work, and the trolley generator is charged from mains or a vehicle inverter between jobs.
Q5: What support is provided after delivery?
Every kit carries a 12 month warranty, lifetime technical support, remote commissioning guidance and a factory calibration report traceable to national standards.
Integrated kit or separate instruments? Separate units bought over time rarely match in impedance and timing, and mismatch shows up as ghost reflections in multiple pulse testing. A factory matched kit removes that risk and gives single source warranty coverage.
What should a tender specification include? Require at least 2048 joules at 32kV, eight-pulse arc reflection, acoustic-magnetic synchronisation with time difference calculation, 11 frequency route tracing, and a calibration certificate for each unit.
How is shipping and training handled? Kits ship in wooden case export packing within 15 to 25 days, and remote or on-site commissioning training can be arranged with the order.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews