logo
Home > Products >
Cable Fault Locator
>
Portable Underground Cable Fault Locator System Kit (3-in-1 Cable Fault Testing Package)

Portable Underground Cable Fault Locator System Kit (3-in-1 Cable Fault Testing Package)

Product Details:
Place of Origin: Shaanxi, China
Brand Name: XZH TEST
Certification: CE, ISO 9001, ISO 14001, ISO 45001
Model Number: XHGG501E / XHGX507C1 / XHDD503
Detail Information
Place of Origin:
Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE, ISO 9001, ISO 14001, ISO 45001
Model Number:
XHGG501E / XHGX507C1 / XHDD503
System Configuration:
3-in-1 Portable Kit
Fault Types Covered:
Open Circuit, Short Circuit, High Resistance Flashover
Pre-Locator Range:
150km Or More, Blind Zone 10m Or Less
Pinpointing Accuracy:
0.1m Or Better
Route Tracing Frequencies:
11 Active Frequencies 640Hz-197kHz
Depth Measurement:
0-20m, Plus Or Minus 5 Percent
Total Kit Weight:
Under 18kg In Three Cases
Battery Endurance:
5 Hours Pre-locator, 20 Hours Standby Pinpointer
Protection Class:
IP54 To IP65
Warranty:
12 Months With Lifetime Technical Support
Highlight:

High Light

Highlight:

Three-in-One Portable Test Kit

,

Ten Inch Touchscreen TDR Ranging

,

500000 Times Signal Gain

Trading Information
Minimum Order Quantity:
1 Set
Price:
USD 8,500-12,000 / Set
Packaging Details:
Three aluminium alloy carry cases packed in one export wooden case with shock-proof foam
Delivery Time:
15-25 working days after deposit
Payment Terms:
T/T,L/C,Western Union
Supply Ability:
40 Sets per Month
Product Description

This portable underground cable fault locator system kit answers a common field problem: the cable crew arrives with one instrument, finds the fault is of a different type, and waits a day for backup equipment. The XZH TEST three-in-one package puts route tracing, distance pre-location and acoustic-magnetic pinpointing into three compact battery powered units that travel in one vehicle and are carried by one technician. The set is built around the XHGG501E pre-locator, the XHGX507C1 multi-frequency pipe and cable locator, and the XHDD503 acoustic-magnetic pinpointer, sized for municipal grids, street lighting circuits, industrial park feeders and renewable energy collection lines where a full trailer mounted system is neither economic nor practical.

Key Advantages
  • One Person, Three Instruments: the whole kit weighs under 18kg in shockproof aluminium cases, so a single technician can trace route, range the distance and pinpoint the defect without a second crew or a cable test van.
  • 10.1 Inch Touchscreen Pre-Locator: the XHGG501E runs low voltage pulse TDR for open and short circuit faults and switches to high voltage flashover current sampling for high resistance breakdowns, with 400MHz sampling, 150km range and 0.07m resolution.
  • 500,000 Times Signal Gain: the XHDD503 pinpointer applies independent dual channel acoustic and electromagnetic amplification with an analogue pointer meter and headphone monitoring, reaching 0.1m accuracy on buried distribution cable.
  • Eleven Frequency Route Tracing: the XHGX507C1 transmitter offers nine power gears across 640Hz to 197kHz, direct, coupling and induction modes, 360 degree cruise navigation and depth reading from 0 to 20m within plus or minus 5 percent.
  • Live Cable Identification: a 200mm flexible Rogowski clamp reads the current signature of a single cable inside a duct bank, so the crew confirms the correct target before any test voltage is applied.
  • Full Day Battery Operation: each unit carries its own rechargeable lithium pack, with more than 5 hours on the pre-locator, 20 hours standby on the pinpointer, and separate chargers supplied for all three cases.
Three-in-One System Components
  • XHGG501E Cable Fault Pre-Locator: 10.1 inch industrial panel PC at 1024x600, low voltage pulse output 300V plus or minus 15 percent, TDR and flashover current sampling methods, waveform memory for more than 8000 records, industrial case weighing about 5.0kg.
  • XHGX507C1 Pipe and Cable Locator: 15W transmitter with 9 gears and 11 active frequencies, 4.3 inch receiver plus 5.0 inch transmitter touch display, direct connection reach up to 20km, real time depth 0 to 20m, transmitter 3.85kg and receiver 2.0kg.
  • XHDD503 Acoustic-Magnetic Pinpointer: acoustic and electromagnetic synchronisation with analog pointer meter, 500,000 times magnification, 3.7V lithium cells with more than 20 hours standby, IP65 shielded vibration probe, host 0.81kg and probe 1.4kg.
Three-Step Field Workflow
  1. Trace and identify: the XHGX507C1 follows the buried route, reads the depth and confirms the target cable with the Rogowski clamp before any fault current is applied.
  2. Range the distance: the XHGG501E applies TDR for low resistance defects or the flashover method for high resistance defects, returning the fault distance measured in metres.
  3. Pinpoint on the ground: the technician walks the pre-located span with the XHDD503 probe, listening to the acoustic signal and reading the magnetic pointer, until the defect is fixed at 0.1m accuracy.
Technical Specifications
ParameterXHGG501E Pre-LocatorXHGX507C1 Path and ID LocatorXHDD503 Pinpointer
Primary FunctionDistance pre-ranging by TDR and flashoverRoute tracing, depth and cable identificationAcoustic-magnetic pinpointing
Signal or OutputLow voltage pulse 300V plus or minus 15 percentTransmitter output up to 300VMagnification 500,000 times
Power and BatteryBuilt-in lithium 11.1V, over 5 hours15W maximum, transmitter 11.1V, receiver 8.4VFour 3.7V lithium cells, standby over 20 hours
Range or DepthRange 150km or more, blind zone 10m or lessDirect 0-20km, depth 0-20m plus or minus 5 percentPinpointing accuracy 0.1m or better
Display Interface10.1 inch TFT touchscreen 1024x6004.3 inch receiver and 5.0 inch transmitter touchPrecision analog pointer meter
Enclosure and WeightIndustrial case, about 5.0kgTransmitter 3.85kg, receiver 2.0kgHost 0.81kg, probe 1.4kg
Operating Environment-10 to 50 degrees Celsius-10 to 55 degrees Celsius-10 to 50 degrees Celsius
Protection LevelIP54 host caseIP65 transmitter and receiverIP65 shielded probe
Standard Packing List
  • XHGG501E package: host, low voltage Q cable 2m, flashover double Q cable 2m, current sampler, ground wire, charger.
  • XHGX507C1 package: 15W transmitter, 3D receiver, transmitting caliper 125mm, flexible Rogowski clamp 200mm, test leads, earth ground spike, two chargers.
  • XHDD503 package: host, vibration ground probe with rod, noise isolating headphones, audio cable, charger.
Applications and Standards

The three unit set suits municipal distribution networks, street lighting maintenance crews, industrial park medium and low voltage feeders, solar photovoltaic collection circuits and wind farm inter-array cables. It is also used for pre-excavation route surveys, cable theft damage investigation, joint failure diagnosis and acceptance checks on newly laid low voltage runs.

Design and testing follow DL/T 849.1, DL/T 849.2, DL/T 846, GB/T 18268.1 and IEC 61010-1 with CAT III 600V rating. Manufacturing is covered by ISO 9001, ISO 14001 and ISO 45001, and each unit is CE marked and burn-in tested before packing.

Technical FAQ

Q1: Can this kit find high resistance faults?
The XHGG501E includes a high voltage flashover current sampling mode for high resistance breakdowns, and the XHDD503 then pinpoints the flashover path acoustically. For sustained high resistance work a surge generator can be added from our four-in-one series.

Q2: How accurate is the depth reading when tracing?
The receiver computes depth from signal gradient and distortion analysis, giving 0 to 20m range within plus or minus 5 percent on undisturbed soil. Recalibration on a known depth takes a few seconds.

Q3: Does the kit work on live cables for identification?
Yes. The Rogowski clamp reads current signatures without breaking the circuit, which is the standard method for confirming a target cable among parallel runs before fault testing begins.

Q4: What training is needed for a new crew?
Most crews are productive after one day. The pre-locator follows a guided workflow, and remote commissioning support is included with the order.

Q5: What is the warranty and service arrangement?
Twelve months full warranty, lifetime technical support, factory calibration report with each unit, and spare probes or clamps shipped from stock.

Buyer Guide

When is a three-in-one kit enough? If your work is mainly low and medium voltage distribution cable up to 10kV, a route tracer, a TDR pre-locator and a pinpointer cover the majority of faults. Teams working regularly above 10kV normally add a surge generator, which is why we also offer a four-in-one configuration.

What should be checked before ordering? Confirm the fault types you meet most often, the deepest cable you expect to trace, whether cable identification on live circuits is required, and whether local calibration certificates are mandatory for acceptance.

Why buy the matched set instead of separate units? The three instruments are calibrated as a set, share battery and cable standards, and arrive in one shipment with one warranty contact, which removes the mismatch problems that appear when instruments from different suppliers are combined.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

S
Saif Al Hammadi
United Arab Emirates Jun 17.2026
This full‑set cable fault testing system (XHHV535‑4TS, XHGG502A, XHDD503C, XHGX507C) performs brilliantly for our DEWA government team. It quickly located underground cable faults at Al Sheraa headquarters in Al Jaddaf, Dubai. Stable under high heat and sandy conditions, the combined modules deliver precise readings, drastically cutting troubleshooting time. Reliable all‑in‑one solution for urban utility maintenance.