Earth Resistance Soil Resistivity Tester XHDJ706 30k Ohm 4 Wire 500 Data

Earth Resistance Soil Resistivity Tester XHDJ706 30k Ohm 4 Wire 500 Data

Product Details:
Place of Origin: Shaanxi
Brand Name: XZH TEST
Model Number: XHDJ706
Detail Information
Place of Origin:
Shaanxi
Brand Name:
XZH TEST
Model Number:
XHDJ706
Gross Weight:
6.3kg
Highlight:

High Light

Highlight:

XHDJ706 Earth Resistance Soil Resistivity Tester

,

Voltage Earth Resistance Soil Resistivity Tester

Trading Information
Minimum Order Quantity:
1unit
Price:
Negotiable
Packaging Details:
carton packaging
Delivery Time:
5-8 work days
Payment Terms:
T/T
Supply Ability:
500 units per month
Product Description
XHDJ706 · EARTH RESISTANCE & SOIL RESISTIVITY
Earth Resistance Soil Resistivity Tester XHDJ706 30k Ohm 4 Wire 500 Data
Telecom & oil field
0.00 Ωm – 9999 kΩm
2 / 3 / 4-wire
4-digit LCD

The XHDJ706 measures ground resistance, soil resistivity and ground voltage in one instrument. Its ground resistance range is 0.01 Ω to 30.00 kΩ, soil resistivity range is 0.00 Ωm to 9999 kΩm, and ground voltage range is AC 0.00 V to 600 V.

The meter supports precision four-wire, three-wire and simple two-wire ground resistance tests. Soil resistivity uses the four-pole Wenner method with an electrode spacing of 1 m to 100 m, calculated as ρ = 2πaR. A four-digit LCD with backlight shows the reading, and 500 groups can be stored for later review.

Product View
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
2/3/4 Digital Earth Resistance Meter Soil Resistivity Tester
Who This Tester Is For

For telecom, computer-room, oil field and gas station teams that maintain grounding and lightning protection systems.

Telecom site and computer-room teams checking equipment grounding and lightning protection before service.
Oil field, gas station and factory electrical teams monitoring grounding grids and equipment grounds.
Lightning protection teams verifying lightning rods and grounding systems, where both resistance and soil resistivity data are needed.
The four-wire method uses the ES auxiliary ground clamped to the same point as E, which removes contact resistance and test-lead resistance from the reading. Three-wire and simple two-wire methods are also provided.
Key Capabilities
One meter for ground resistance, soil resistivity and ground voltage; no separate resistivity meter is needed for the same test point.
Precision four-wire measurement removes contact and lead resistance; three-wire and simple two-wire tests are available where auxiliary rods cannot be spaced normally.
Soil resistivity by the four-pole Wenner method, with electrode spacing from 1 m to 100 m and direct display in Ωm or kΩm.
Ground resistance 0.00 Ω – 30.00 kΩ with automatic range shift and 0.01 Ω resolution at the low end.
Ground voltage AC 0.00 V – 600 V; the meter also checks interface connection, interference voltage and interference frequency.
500 groups of data storage with MEM and FULL indications, plus on-meter data review and deletion.
Four-digit LCD, 111 mm × 68 mm, with off-white backlight; LED flashes during measurement.
Alarm for resistance, ground voltage and soil resistivity; APO auto power-off after 15 minutes; powered by 6 × 1.5 V LR14 batteries.
Measuring Range and Accuracy
RangeAccuracyResolution
Ground resistance (R)0.00 Ω – 30.00 Ω±2 % rdg ± 5 dgt0.01 Ω
Ground resistance (R)30.0 Ω – 300.0 Ω±2 % rdg ± 3 dgt0.1 Ω
Ground resistance (R)300 Ω – 3000 Ω±2 % rdg ± 3 dgt1 Ω
Ground resistance (R)3.00 kΩ – 30.00 kΩ±2 % rdg ± 3 dgt10 Ω
Soil resistivity (ρ)0.00 Ωm – 99.99 Ωmρ = 2πaR0.01 Ωm
Soil resistivity (ρ)100.0 Ωm – 999.9 Ωmρ = 2πaR0.1 Ωm
Soil resistivity (ρ)1000 Ωm – 9999 Ωmρ = 2πaR1 Ωm
Soil resistivity (ρ)10.00 kΩm – 99.99 kΩmρ = 2πaR10 Ωm
Soil resistivity (ρ)100.0 kΩm – 999.9 kΩmρ = 2πaR100 Ωm
Soil resistivity (ρ)1000 kΩm – 9999 kΩmρ = 2πaR1 kΩm
Ground voltageAC 0.00 V – 600 V±2 % rdg ± 3 dgt0.01 V
Technical Specifications
ParameterSpecification
FunctionTwo-wire, three-wire and four-wire ground resistance; soil resistivity; ground voltage
Ground resistance range0.00 Ω – 30.00 kΩ, automatic range shift
Soil resistivity range0.00 Ωm – 9999 kΩm, automatic range shift
Ground voltage rangeAC 0.00 V – 600 V
Measurement methodGround resistance: rated current change-pole method; soil resistivity: four-pole Wenner method; ground voltage: average rectification
Test frequency128 Hz
Short-circuit test currentAC > 20 mA, sine wave
Open-circuit test voltageAC 28 V max
Electrode spacing1 m – 100 m, settable
Display4-digit large LCD, 111 mm × 68 mm; display field 108 mm × 65 mm; off-white backlight
Data storage500 groups; MEM storage indication; FULL symbol when full
Power supply6 × 1.5 V LR14 alkaline batteries (9 V); continuous standby > 100 hours
Automatic shut-downAPO indication; auto power-off after 15 minutes
Dimensions240 mm (L) × 188 mm (W) × 85 mm (H)
WeightInstrument 1280 g including battery; test line 1300 g; auxiliary ground rods 720 g (4 pieces)
Operating conditions-10 °C – 40 °C; < 80 % RH
Storage conditions-20 °C – 60 °C; < 70 % RH
Overload protectionGround resistance: AC 280 V / 3 s between H-E and S-ES ports
Insulation resistance≥ 20 MΩ at 500 V between circuit and case
Withstand voltageAC 3700 V/rms between circuit and case
StandardsIEC61010-1 (CAT III 300 V, CAT IV 150 V, pollution degree 2); IEC61010-031; IEC61557-1; IEC61557-5; JJG 366-2004; IEC61326 (EMC)
Frequently Asked Questions
Q1.Can it test lightning rod and computer-room grounding?
Yes. The meter is suitable for lightning rods, computer rooms, telecom sites, factory grounding grids and building grounding. It measures ground resistance and ground voltage, and can also measure soil resistivity at the same site.
Q2.How does the simple two-wire ground test work?
The simple two-wire method uses an existing low-resistance ground, such as a metal water pipe or building ground, as the auxiliary electrode. The meter reading RE is the sum of the tested ground RX and the auxiliary ground re, so RX = RE − re.
Q3.How is soil resistivity calculated?
Soil resistivity uses the four-pole Wenner method. With electrode spacing a in metres and resistance R in ohms, the meter calculates ρ = 2πaR in Ωm; a can be set from 1 m to 100 m.
Q4.What display and storage does it have?
It has a four-digit large LCD of 111 mm × 68 mm with off-white backlight and a 108 mm × 65 mm display field. It stores 500 groups, shows MEM when storing and FULL when memory is full.
Q5.What safety rating does the tester have?
IEC61010-1 CAT III 300 V and CAT IV 150 V, pollution degree 2; IEC61010-031; IEC61557-1; IEC61557-5; JJG 366-2004; IEC61326 EMC. Insulation resistance is at least 20 MΩ at 500 V, and withstand voltage is AC 3700 V/rms between circuit and case.
Grounding test check
Send the grounding system type, test range and site conditions, and we will confirm the XHDJ706 configuration and accessories.