logo
Send Message
Home > products >
Cable Fault Locator
>
Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: CE
Model Number: XHHV535-4TS
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE
Model Number:
XHHV535-4TS
Impulse Voltage:
0~32kV、0~16kV、0~8kV(Adjustable)
High Voltage Partial Pressure:
1.5 Level
Built-in Capacitor:
4μF/32kV、16μF/16kV、64μF/8kV
Discharge Power:
2048J @each Voltage Level
Impact Time:
About 7 Seconds For Automatic Impact, Arbitrary Control Time For Manual Impact
Surge Power:
2KVA
Burn Current:
60mA At 32kV, When Voltage Go Down, The Current Increase Large
Working Power Supply:
AC 220V±10% / 50Hz/60Hz
Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
8-15 work days
Payment Terms:
T/T
Supply Ability:
50 units/months
Product Description

The XHHV535-4TS high voltage pulse generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.

 

This device integrates a high-voltage DC source, an energy storage capacitor, a discharge ball device, an automatic discharge device, and a voltage level switching device into a cart-type high-end experimental instrument. It is a trolley-type high-end experimental instrument. The equipment completely solves the problems of ease of use, portability, safety and reliability of traditional experimental devices.

 

When the XHHV535-4TS trolley-type high-voltage pulse generator is in use, after selecting the function switch, press the start button to perform high-voltage boosting work. After use, press the stop button, and the internal system will automatically release the remaining high voltage on the accumulator.

 

The high voltage surge generator also has the function of zero-start protection, which can make the operation of the device more safe and reliable. It has super short-circuit protection function, which can make the high-voltage output work directly to the ground. With three-gear voltage range and capacitance capacity switching function, users can choose different equipment voltage adaption gears according to different cable voltage needs, making the test process easier.

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 0


Panel introduction

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 1

 

1. Ammeter: Indicates the size of the current.


2. Voltmeter (Voltmeter): high-voltage output voltage indicating kV meter, divided into 8kV, 16kV, 32kV combined with voltage level switch readings.


3. High-voltage lamp (HV): On means there is high-voltage output, and off means there is no high-voltage output.


4. Power light: When the power switch is turned on, the indicator light lights up.


5. Zero light (Zero): Indicates that the voltage regulating knob is in the zero position. Only when the zero light is on can the high voltage be started.


6. Overcurrent protection switch: When pressed, it indicates that the overcurrent protection function has started; when it pops up, it indicates that the instrument has triggered the overcurrent protection.


7. Power Switch: Turn clockwise to turn on the system power supply, turn counterclockwise to turn off the system power supply.


8. Single key (Single): This key is effective when the mode selection key is in the Single function.


9. Mode select: divided into three modes: voltage resistance (DC), single (Single), and cycle (Cycle). DC is the voltage withstand function. When this function is selected, the cable will be tested for voltage resistance at this time; Single is the manual function. When this function is selected, the voltage will increase after the high voltage starts. Press the Single key to manually trigger the impact discharge; Cycle is an automatic function. When this function is selected, the high voltage is started to boost the voltage. The instrument will automatically trigger impulse discharge for about 7 seconds.


10. Start button: In the zero position, press the start button. At this time, the high voltage starts and the high voltage light turns on. In the non-zero state, the starting high-pressure light does not light up.


11. Voltage control: When this knob is in the zero position, the zero light is on and the high voltage can be started. Only after the high voltage is started can the voltage be boosted through the voltage regulating knob.


12. Stop key: When the test is completed or an abnormality occurs, press this key to cut off the high-voltage output. At this time, the remaining high voltage under test will also be automatically discharged.


13. Voltage rotation mode (Voltage select): This button has three voltage level modes, 8kV, 16kV, and 32kV. Please rotate it to the appropriate position before turning on the machine. Lift, turn, press.

 

 

 

Side panel description

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 2

 

 

 

1. Power socket (220V 50Hz): instrument working power supply, AC220V connection port;

 

2. Fuse Holder: Where the fuse holder of the AC220V power supply system is installed;

 

3. Communication socket (Signal): Use double Q lines to connect the unit and the cable fault tester to collect waveforms during flashover. This is only valid during high-voltage flashover.

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 3

 

Back panel indication

 

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 4

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 5

 

1. Safety GND: The ground of the instrument shell. In order to prevent the instrument shell from being electrified or people getting electric shock, it must be reliably connected to the earth.

 

2. High-voltage ground (HV GND): Also called high-voltage tail, it must be reliably grounded to prevent high-voltage leakage and discharge. Poor contact may result in failure to boost voltage, high-voltage breakdown and damage to internal components of the instrument, and safety accidents caused by leakage or discharge within the instrument.

 

3. Sampling GND: The negative terminal of the pulse energy storage capacitor has a high voltage and must be reliably grounded. It is used for sampling when the waveform is sampled under the high voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).

 

4. High voltage output (HV OUT): dedicated DC high voltage output terminal.

 


Technical parameters

 

 

 

 

 

 

 

 

 

 

High voltage surge generator XHHV535-4TS

Surge voltage levels and adjustment

ranges

Level 1 : 0-8KV

Level 2: 0-16KV

Level 3: 0-32KV

Surge voltage levels switch Manual
Voltage adjustment type Continuous
Indication High-voltage side voltage metering, indication of output voltage and current in real time
Surge energy at each level Up to 2048J
Operating mode Single trigger, cycle, DC
Operating modes switch Manual
Impact time about 5 seconds for automatic impact, arbitrary control time for manual impact
Impact power 2KVA
Continuous output current 60mA
Built-in capacitor 4μF/32kV, 16μF/16kV, 64μF/8kV three-speed adjustment
Safe protection With zero start protection function, safe and reliable
Discharge Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device
Working power AC 220V±10% 50Hz±2Hz (other voltage and frequency can be customized)
DC withstand voltage testing

Output voltage adjustment and

indication range 0-32KV, Output current indication range 0-20A

Burn current

Fault conditioning (burning) with current up to

60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV.

Connecting cable High voltage output cable: 5m, Protective earthing cable:5m,power cord 2.5m
Safety

Over-voltage, Over-current, Overheating protection.

Automatic discharge after operation.

Protection rating Not lower than IP54
Working power AC 220V±10% 50Hz±2Hz(other voltage and 60Hz optional)
Dimensions(mm) 534L×444W×805H
Total weight About 120kg

 


Packing list

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 6

 

The length of high voltage output cable, ground wires and power cable can be customized.

 

The default standard length is: 5 meters for high voltage output cable, 5 meters for ground cable, and 3 meters for power cord. 

 

The test cable shown in the figure below is an extended test cable, which can be customized from 10 meters to 50 meters.

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 7

 

 

 

 


Onsite test 

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 8Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 9

 


 

Company profile

 

XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.

Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.

 

What we can do

We have the ability to innovate new products and technologies.

We can provide complete system solutions for your project.

We provide online and offline practical and theoretical training.

We provide instrument repair and calibration.

 

Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 10Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 11Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 12Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 13Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 14Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 15Trolley Portable 8/16/32kV 2000J High Voltage Surge Generator For Underground Cable Fault Location 16


FAQ

 

1. Are you a trading company or a manufacturer?
We are a professional manufacturer with more than 10 years of experience. We can strictly control the quality of parts and finished products.

 

2. What is the delivery time and inventory?
If our best-selling products are in stock, it will be 5-8 working days for shipment. But for mass production and customized production, the time will take 2-4 weeks.

 

3. What are your payment terms?
Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can be negotiated.

 

4. How long is your product warranty?
We provide 1 year warranty for the equipment.

 

5. How do you ensure quality?
The product links include R&D, manufacturing, commissioning and technical support, following strict and scientific management principles. Therefore, we can support strong production and R&D capabilities, and can produce high-quality products at competitive prices to meet customers' high requirements.

 

6. What support can I get?
We will provide training support, marketing support, technical support and supply chain support. You can contact us for more information.

 

7. Where is your factory? Can I visit your factory?
We are located in Xi'an, Shaanxi, China. We are close to Xi'an Xianyang International Airport, which is about 2 and half hours by plane from Shanghai and Guangzhou. All customers from all over the world are welcome to visit us.

 

8. How to become your dealer?
Every company interested in power system instruments can contact us without hesitation, including website letters, emails, telephones, etc. We will contact you quickly according to your company information and cooperation intentions.