logo
Home > products >
Cable Fault Locator
>
HV Pulse Generator 8/16/32 kV Three Voltage Customized Trolley Surge Generator

HV Pulse Generator 8/16/32 kV Three Voltage Customized Trolley Surge Generator

Product Details:
Certification: CE, ISO
Detail Information
Certification:
CE, ISO
Model NO.:
XHHV535-4TS
Power:
Electricity
Customized:
Customized
Color:
Black
Transport Package:
Wooden Case
Specification:
534× 444× 805mm
Trademark:
XZH TEST
Origin:
China
HS Code:
8543201000
Supply Ability:
2000PCS/Year
Customization:
Available
After-sales Service:
Warranty Certificate
Warranty:
12 Months
Product Description


   Manufacturer Trolley Surge Generator 8/16/32 Kv Three Voltage High Voltage Pulse Generator                                                           

 
XHHV535-4TS (three-gear voltage regulation)  8KV/16KV/32KV  High voltage surge generator



Product description:

Trolley cable fault locator  is mainly used for underground cable fault locator test of voltage level of 35kV and below;
And the torlley high voltage impulse generator can also be used for DC withstand voltage test of other electrical equipment.

The device integrates DC high voltage source, energy storage capacitor and discharge ball gap  tdr cable fault tester in one body.
which 
adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology,
it makes the whole structure simple.  
In order to preserve the habit of using the transformer and the operating box to generate DC high voltage,
the pulse generator adopts the humanized design operation mode, which is safe and reliable. 



Technical Parameters:
 

 
Voltage Range: 8/16/32KV three-stage voltage
High voltage divider: Voltage Accuracy 1.5 grade
Inside capacitor : 4/16/64microfarad   three-stage
Surge time: Auto surge about 5s, also can control by hands.
Discharge energy: 0-2048J @ each voltage level   
Surge power: 2KVA(2000W)
Impact time 3-10 seconds/time,   manually adjustable
Size:  520L×360W×950H 
Weight:  about 98kg(4uF)
Power supply:  AC 220V + 10% 50Hz/±2Hz
Environment temperature:  -20 ~ +50 ºC
 




Main Functions:
1. With overcurrent, overvoltage, overheating automatic protection;
2. High voltage pulse output is uniform and controllable;
3. Super short circuit protection function can make the high voltage output directly short to ground;
4. With a current and voltage double 1.5 level pointer display, intuitive and clear, the impact discharge process is clear at a glance;
5. High-voltage side voltage measurement, real-time and accurate; serial micro-ampere meter can be used as straight high hair;
6. With zero start protection, and potentiometer zero output function, safe and reliable;
7. Unique high voltage measurement design, the voltmeter can indicate the capacitor voltage in real time in the stop state.



Manufacturer Trolley Surge Generator 8/16/32 Kv Three Voltage High Voltage Pulse Generator
Manufacturer Trolley Surge Generator 8/16/32 Kv Three Voltage High Voltage Pulse Generator
Manufacturer Trolley Surge Generator 8/16/32 Kv Three Voltage High Voltage Pulse Generator

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Manufacturer Trolley Surge Generator 8/16/32 Kv Three Voltage High Voltage Pulse Generator



 
Panel function description
 
1. Ammeter: Show the current of low voltage side
 
2. Voltmeter:High-voltage output voltage indication kV meter, divided into 8kV,  16kV, 32kV combined with voltage level switch readings.
 
3. High-voltage light(HV):On means there is high voltage output, and off  means there is no high voltage output.
 
4.Power:After turning on the power switch, the indicator light is on, indicating  that the AC220V is normal.
 
5. Zero light(Zero):Indicates that the pressure regulating knob is in the zero  state, and the start key is effective only when it is on.
 
6. Overcurrent protection:Connect the device and the cable fault tester with the double Q wire to  collect the flashover waveform, which is valid only for high-voltage flashover.
 
7. Power switch(NO/OFF): AC 220V 50Hz power input socket. Fuse holder and  main power switch of device. 8A Fuse.
 
8. Single:The indicator will light when choose single discharge.
 
9. Mode selete: DC,Single,Cycle.  DC model is to start withstand voltage test( hipot test) to cable.  Single model is discharge by hand controlling. Press it and then adjust High voltage  knob to control discharge time by hand.
 
Cyclic model is discharged automatically which means select this function to rise up  voltage after start high voltage ,this device will be automatic trigger impulse  discharge, time is about 5 seconds.
 
10. Start:In the zero position, press the start button, and the high voltage starts at this time, and the high voltage light is on. In the non-zero state, the high-voltage  lamp does not light up when starting.
 
11.Voltage control:When this knob is in the zero position, the zero position  light is on, and the high voltage can be started. After the high pressure is started,  the pressure can be increased through the pressure regulating knob.
 
12. Stop: When the test is completed or an abnormality occurs, press this key to  cut off the high voltage output. At this time, the remaining high voltage in the test  stop will also be automatically discharged.
 
13. Voltage select: This key has three voltage level modes, 8kV, 16kV, and  32kV. Please rotate it to a suitable position before turning on the machine. Lift,  rotate, press.