50kV VLF Hipot Tester XHDP Series Ultra Low Frequency AC High Voltage Generator

50kV VLF Hipot Tester XHDP Series Ultra Low Frequency AC High Voltage Generator

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHDP series
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHDP series
Model NO.:
XHDP Series 50KV
Specification:
420*250*340mm
Trademark:
XZH TEST
HS Code:
9030339000
Supply Ability:
1000 Pieces /Year
Customization:
Available
Warranty:
Warranty Certificate
Highlight:

High Light

Highlight:

50KV VLF hipot tester

,

ultra low frequency AC generator

,

high voltage hipot tester with warranty

Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
5-8 days
Payment Terms:
T/T
Supply Ability:
2000 PCS/Year
Product Description
XHDP SERIES · 50 kV SINGLE BOOSTER
50kV VLF Hipot Tester XHDP Series Ultra Low Frequency AC High Voltage Generator
50 kV peak
≤ 6 µF load
4 kg controller + 25 kg booster

This 50 kV XHDP unit is the single-booster version of the series: one 4 kg controller and one 25 kg booster, connected by the supplied multi-core cable. It produces an ultra-low frequency AC test voltage for cables and motors and is small enough for a two-person crew to move without a trolley.

Control is fully electronic. Boost, step-down, measurement and protection are automatic, the colour touch screen shows the waveform, and the test result can be printed on the spot.

Product View
30kv-90kv Optional Vlf 0.1Hz Cable Tester AC/DC Withstand Voltage Tan Delta Test Kit
Who This Set Is For

This is the practical choice for 10 kV and 15 kV distribution work where the test point is reached on foot.

Urban distribution maintenance teams testing 10 kV and 15 kV cable sections between manholes and ring main units.
Motor repair shops checking rewound stators and small complete machines before they go back into service.
Industrial plants that keep one set on site for scheduled shutdown testing rather than calling in a contractor.
The instrument is meant for large-capacitance loads. Zinc oxide arresters and other small-capacitance or resistive samples fall outside its range.
Key Features
50 kV peak output with a load capacity of ≤ 6 µF, matched to cables and motors within 15 kV.
Single-link structure: no second booster, no series line, and only two cases to carry.
Voltage resolution 0.1 kV and current resolution 0.1 mA, both at 3% accuracy, with peak error and waveform distortion within 3%.
Protection values are computed from the sample capacitance and the test voltage, so nothing has to be set manually.
Discharge events and voltage or current step-changes are caught by the same protection circuit, which acts in under 20 ms.
The 90-group memory and the built-in printer keep a record for each test without extra equipment.
Technical Specifications
Rated voltageLoad capacityStructure and weightApplication range
50 kV (peak)≤ 6 µFSingle booster; controller 4 kg, booster 25 kgCables and motors within 15 kV
General parameterValue
Output rated voltage30 kV – 80 kV, in the steps listed above
Output frequencyAutomatic conversion, 0.1 Hz – 0.01 Hz
AC voltage resolution0.1 kV
Voltage accuracy3%
AC current resolution0.1 mA
AC current accuracy3%
Voltage positive and negative peak error≤ 3%
Voltage waveform distortion≤ 3%
Operating conditionsIndoor and outdoor; -10 °C to +40 °C; humidity ≤ 85% RH
Input power50 Hz, 220 V ±5% or 60 Hz, 110 V ±5%
Test Procedure
1.Connect the controller to the booster with the multi-core cable, then select the single-link diagram on the touch screen.
2.Enter the test voltage and a hold time between 1 and 99 minutes.
3.Start the test; the instrument pre-tests the sample and measures capacitance in the first cycles.
4.Hold the voltage while overvoltage, overcurrent, step-change and discharge protection stay active.
5.Stop automatically or manually; the shutdown sequence discharges the sample.
6.Print the result or recall it later, then disconnect power before removing any test lead.
Standard Package
Controller × 1
Voltage booster × 1
High voltage connection cable × 1
Multi-core connection cable × 1
Power cord × 1
Discharge rod × 1
Ground wire × 2
Compensating capacitor × 1
Printing paper × 2
Fuse × 2
Safety and Maintenance
Connect the test leads before the power cable and remove them in the reverse order.
Discharge with the rod and then short-circuit the sample before handling it.
Keep the booster clear of metalwork and standing water during the test.
If the display does not light, check the fuse and the input circuit before arranging service.
Frequently Asked Questions
Q1.What is the maximum load at 50 kV?
The 50 kV level carries ≤ 6 µF, which is the figure to check against the capacitance of the cable or winding being tested.
Q2.Which cable classes does it cover?
Cables and motors within 15 kV. The 50 kV peak output leaves the headroom the test procedure expects above the cable's rated voltage.
Q3.How heavy is the set?
The controller weighs 4 kg and the booster 25 kg. There is no second booster and no series line in this configuration.
Q4.Is the frequency adjustable?
Frequency conversion is automatic from 0.1 Hz to 0.01 Hz; the instrument selects the working frequency after measuring the sample capacitance.
Q5.Can it be used on a short cable?
Yes, but below about 100 metres the waveform may lose its sine shape. A compensating capacitor connected in parallel at the test end corrects this.
Configuration check
Tell us the cable class and the capacitance of the section you test most often, and we will confirm the 50 kV single-booster configuration.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.