logo
Home > Products >
Transformer Tester
>
Transformer Low Voltage Short Circuit Impedance Tester for Winding Deformation Diagnostic Analysis|XHZK1620

Transformer Low Voltage Short Circuit Impedance Tester for Winding Deformation Diagnostic Analysis|XHZK1620

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: CE, ISO
Model Number: XHZK1620
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
CE, ISO
Model Number:
XHZK1620
Model NO.:
XHZK1620
Power:
Electricity
Customized:
Customized
Color:
Black
Transport Package:
Wooden Box With Foam Inside
Specification:
350 *270 *170mm
HS Code:
9030332000
Supply Ability:
1000pieces/Year
Customization:
Available
Warranty:
1 Year
Highlight:

High Light

Highlight:

XHZK1620 Transformer Short Circuit Impedance Tester

,

Low Voltage Winding Deformation Diagnostic Measurement

,

Three-Phase Automatic 0.2-Grade Impedance Analysis

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden case
Delivery Time:
5-8 days
Payment Terms:
T/T
Supply Ability:
1000 PCS/Year
Product Description
Transformer Low Voltage Short Circuit Impedance Tester|XHZK1620 
Product Overview

Short-circuit impedance is a fundamental parameter for assessing transformer winding integrity. The short-circuit impedance method is the traditional and most reliable approach for detecting winding deformation, and per GB1094.5-2003 and IEC60076-5:2000 standards, the variation of short-circuit reactance is the sole criterion for determining whether transformer windings have sustained mechanical deformation. The XHZK1620 Low Voltage Short Circuit Impedance Tester implements this critical diagnostic method with automated precision, eliminating the need for complex external equipment.

Powered entirely from a single-phase 220V AC source (or a small 500VA online UPS when mains power is unavailable), the XHZK1620 completes three-phase measurement in a single automated sequence—connect once, start once, and the instrument automatically measures and displays short-circuit impedance, short-circuit reactance, and three-phase impedance voltage for all phases. With 0.2-grade voltage/current accuracy, automatic frequency correction, and 1000+ result non-volatile storage, it is the definitive portable solution for transformer winding condition assessment in manufacturing, commissioning, and preventive maintenance applications.

XHZK1620 

Key Features
  • Single-Phase 220V Operation: Complete three-phase measurement using only standard mains power—no external voltage regulators or auxiliary equipment required. Compatible with small 500VA online UPS for field sites without grid access
  • One-Click Automated Measurement: Single wiring connection, single start command—the instrument automatically sequences through all three phases and displays results without operator intervention
  • Dual Power Mode: Internal power mode uses instrument's built-in supply; external power mode accepts voltage regulator input for specialized test requirements
  • Comprehensive Parameter Display: Simultaneously measures and displays voltage, current, power, and frequency for each test phase alongside impedance and reactance values
  • Automatic Frequency Correction: Real-time compensation for mains frequency fluctuations eliminates measurement errors caused by unstable grid conditions
  • 0.2-Grade Precision: High-accuracy voltage and current measurement (0.2 grade) with 0.5-grade impedance and power analysis for reliable winding deformation assessment
  • 1000+ Result Storage: Built-in non-volatile memory with perpetual calendar and clock—measurement data preserved indefinitely without power
  • Large LCD Display: High-contrast screen with Chinese/English menu navigation and intuitive operation prompts for international deployment
  • Built-in Thermal Printer: Immediate on-site printing of test results for documentation and reporting
  • Portable & Lightweight: Compact 8kg design (350x270x170mm) with rugged construction for reliable field and laboratory use
Technical Specifications
Measurement Performance
Voltage Range 20V ~ 400V
Current Range 0.5A ~ 10A
Voltage / Current Accuracy 0.2 Grade
Impedance Accuracy 0.5 Grade
Power Accuracy 0.5 Grade (cosφ>0.15)
Measurement Capabilities
Primary Parameters Short-Circuit Impedance, Short-Circuit Reactance, Three-Phase Impedance Voltage
Auxiliary Display Voltage, Current, Power, Frequency (Per Phase)
Reference Standards GB1094.5-2003, IEC60076-5:2000
Frequency Correction Automatic Real-Time Compensation
Power & Interface
Power Supply Single-Phase AC 220V (Internal) or External Voltage Regulator
Alternative Power Compatible with 500VA Online UPS
Display Large LCD (Chinese/English)
Data Storage 1000+ Results, Non-Volatile Memory, Perpetual Calendar
Printer Built-in Thermal Printer
Physical Specifications
Dimensions 350 × 270 × 170mm
Weight 8kg
Frequently Asked Questions
Q1: Why is short-circuit impedance testing critical for transformer winding assessment?
Short-circuit impedance is the definitive parameter for detecting mechanical deformation in transformer windings. Per GB1094.5-2003 and IEC60076-5:2000, any significant change in short-circuit reactance indicates winding deformation—a condition that may not be visible externally but can lead to catastrophic failure under fault conditions. Winding deformation can occur due to transportation damage, through-fault current events, or aging. The XHZK1620 provides rapid, non-invasive impedance measurement to identify these conditions before they cause unplanned outages, making it an essential tool for transformer commissioning, post-fault assessment, and preventive maintenance programs.
Q2: How does the XHZK1620 simplify field testing compared to traditional impedance measurement methods?
Traditional short-circuit impedance measurement requires external voltage regulators, power supplies, multiple measuring instruments, and complex multi-step manual procedures. The XHZK1620 eliminates all of this—connect the test leads to the transformer once, press start, and the instrument automatically sequences through all three phases, measuring and displaying short-circuit impedance, reactance, and impedance voltage. The internal power supply provides all necessary excitation from a standard 220V outlet, and automatic frequency correction compensates for grid instability. For remote sites without mains power, a compact 500VA online UPS is sufficient to power the entire test.
Q3: What is the difference between internal and external power supply modes?
Internal power mode uses the instrument's built-in regulated supply, automatically controlling output voltage and current without any external auxiliary equipment—ideal for routine field testing. External power mode accepts input from an external voltage regulator, providing greater flexibility for specialized testing scenarios requiring non-standard voltage levels or when testing very large power transformers that demand higher excitation current. Both modes benefit from the XHZK1620's automatic frequency correction and one-click three-phase sequencing.
Q4: How does the automatic frequency correction improve measurement reliability?
Transformer short-circuit impedance measurements are frequency-dependent—even minor grid frequency fluctuations can introduce significant errors. The XHZK1620 continuously monitors the power supply frequency and applies real-time mathematical correction to all impedance and reactance calculations. This ensures measurement accuracy even when operating from unstable generators or in regions with poor grid quality, eliminating a major source of measurement uncertainty in field environments where controlled laboratory power is unavailable.
Q5: What are the MOQ, warranty coverage, and included accessories for the XHZK1620?
The minimum order quantity is 1 unit, with payment via T/T. Standard delivery is 5-8 working days in a protective wooden case with internal foam padding. Each XHZK1620 includes the main instrument, complete test lead set, power cord, thermal printer paper roll, spare fuses, and comprehensive user manual. The instrument carries a 12-month warranty covering manufacturing defects, with lifetime technical support. Annual supply capacity reaches 1,000 units, and OEM/ODM customization is available. For volume pricing or technical consultation, please contact our sales team.