A custom-built DC high voltage generator that spans 60 kV to 300 kV. The voltage, current and power class are fixed at order, so the set matches a test list rather than a catalogue page.
A 300 kV DC test is used for high-voltage apparatus that cannot be assessed at a lower voltage: long cable sections, high-ratio transformers and arresters rated for transmission class systems. The same platform is also built at 60 kV and 120 kV for distribution work, which is why the range is quoted as a custom span rather than a single model.
Three numbers define the set: the highest output voltage, the output current at that voltage, and the power class. The tables below list the standard combinations used for quotation. A requirement outside them is quoted as a custom configuration, not as a stock rating.
The 2/3 mA class is used where the specimen capacitance is modest and the test is about voltage stress. The 5/10 mA class charges larger specimens faster and is chosen when test time on long cable matters. Both provide a DC output and the 0.75UDC-1mA reference function.
| 60 - 120 kV configurations | Output voltage | Output current | Output power | Charging current | Control box | Multiplier |
|---|---|---|---|---|---|---|
| 60 kV / 2 mA | 60 | 2 | 120 | 3 | 11.6 | 2.3 |
| 60 kV / 3 mA | 60 | 3 | 180 | 4.5 | 11.6 | 2.3 |
| 120 kV / 2 mA | 120 | 2 | 240 | 3 | 13 | 3.2 |
| 60 kV / 5 mA | 60 | 5 | 300 | 7.5 | 11.6 | 2.3 |
| 200 - 300 kV configurations | Output voltage | Output current | Output power | Charging current | Control box | Multiplier |
|---|---|---|---|---|---|---|
| 200 kV / 2-3 mA | 200 | 2 / 3 | 400 / 600 | 3 / 4.5 | 13.1 | 23 |
| 300 kV / 2-3 mA | 300 | 2 / 3 | 600 / 900 | 3 / 4.5 | 13.1 | 26 |
| 200 kV / 5-10 mA | 200 | 5 / 10 | 1000 / 2000 | 7.5 | 13.1 | 23 |
| 300 kV / 5-10 mA | 300 | 5 / 10 | 1500 / 3000 | 7.5 / 15 | 13.1 | 26 |
| Parameter | Value |
|---|---|
| Voltage measurement error | <= 1.0 % (full scale) +/- 1 digit |
| Current measurement error | <= 1.0 % (full scale) +/- 1 digit |
| Ripple factor | <= 0.5 % |
| 0.75UDC-1mA button | Precision <= 1.0 % |
| Working mode | 30 min at rated load; 10 min at 1.1 times rated voltage |
200 kV and 300 kV are built to order. The 60 kV and 120 kV configurations are the more common builds; the 300 kV unit is quoted against a specific test list.
No. The multiplier and the power stage are built for the ordered voltage. A lower voltage requirement should be ordered as its own configuration.
The highest test voltage, the specimen type and capacitance, the current needed at that voltage, and the supply available on site.
Send the test list with voltage, capacitance and duty cycle, and we will return a configuration with the multiplier, power class and accessories matched to it.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews