The XHYB series puts two oil-immersed AC/DC test ratings on one control platform: a 50 kV model for 10 kV and 35 kV work, and a 100 kV model for 66 kV and 110 kV equipment.

The series is built around the same oil-immersed step-up transformer principle and the same control box. The smaller unit delivers 50 kV AC at 200 mA and 70 kV DC at 100 mA. The larger unit delivers 100 kV AC at 100 mA and 140 kV DC at 100 mA. Both are rated 10 kVA, both run for 30 minutes at rated output, and both use a hand-driven autotransformer with overcurrent and time relays.
The 50 kV model is the match for 10 kV and 35 kV cable, distribution transformers, motors and switchgear. The 100 kV model steps up to 66 kV and 110 kV cable, power transformers, bushings and substation cubicles. Choosing by the specimen class rather than by the highest available voltage keeps the test set, the leads and the clearances proportionate to the work.
In both models the core and windings sit in an oil-filled tank. The oil provides dielectric strength and carries heat from the coils, which is what keeps a 10 kVA transformer compact enough to move between test positions. The control box is separate, connected to the transformer primary by a cable, so the operator stands away from the high-voltage side during a test.
AC is used for the withstand proof at power frequency. DC is used for leakage current measurement, where the capacitive charging current of the specimen is blocked and the microammeter shows the true leakage. The change is made by adding the high-voltage silicon stack and filter capacitor, and the DC amplitude is about 1.41 times the AC rms value.
| Model | Mode | Output voltage | Output current | Capacity | Input | Ratio |
|---|---|---|---|---|---|---|
| XHYB-5/50 | AC | 50 kV | 200 mA | 10 kVA | 220/380 V, 50/26 A | 500 |
| XHYB-5/50 | DC | 70 kV | 100 mA | - | 380 V, 50/26 A | 500 |
| XHYB-10/100 | AC | 100 kV | 100 mA | 10 kVA | 200/380 V, 50/26 A | 1000 |
| XHYB-10/100 | DC | 140 kV | 100 mA | - | 380 V, 50/26 A | 1000 |
The 50 kV model covers 10 kV and 35 kV cable classes. The 100 kV model is intended for 66 kV and 110 kV equipment, where the higher voltage and larger clearances are required.
Yes. Each model produces AC and DC from the same transformer, with the DC output taken through a rectifier and filter. The control box and safety sequence are shared.
The set is supplied with a matching control box, test lines, a power cord, a high-voltage wire and a ground wire. A discharge rod is used after the test.
Send the specimen list with voltage class and test type, and we will mark which XHYB rating covers each item.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews