Cable VLF Hipot Tester XHDP Series 30kV-80kV Voltage Withstand Testing Equipment

Cable VLF Hipot Tester XHDP Series 30kV-80kV Voltage Withstand Testing Equipment

Product Details:
Place of Origin: China
Brand Name: XZH Test
Certification: CE, ISO
Model Number: XHDP Series
Detail Information
Place of Origin:
China
Brand Name:
XZH Test
Certification:
CE, ISO
Model Number:
XHDP Series
Model NO.:
XHDP Series
Power:
Electricity
Customized:
Customized
Color:
Black
Transport Package:
Wooden Box Filled With Foam Inside
Trademark:
XZH TEST
Origin:
China Xi′an
HS Code:
9030339000
Supply Ability:
1000pieces/Year
Customization:
Available
After-sales Service:
Warranty Certificate
Warranty:
12 Months
Highlight:

High Light

Highlight:

VLF Hipot Tester for cable testing

,

AC DC Hipot Tester 30kV-80kV

,

XHDP Series high voltage tester

Trading Information
Minimum Order Quantity:
1unit
Packaging Details:
wooden box
Delivery Time:
5-8work days
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description
VLF Hipot with Tan Delta

Cable VLF Hipot Tester XHDP Series 30kV-80kV Voltage Withstand Testing Equipment

A portable 0.1 Hz AC withstand set for cable and motor insulation, with tan delta measurement taken during the same test and a controller shared across the 30-80 kV range.

30 - 80 kV peak
0.1 - 0.01 Hz auto
Tan delta measurement
4 kg controller

Overview

The XHDP series is a portable AC withstand voltage set built around digital frequency conversion and microcomputer control. Boost, step-down, measurement and protection run automatically, and the colour touchscreen shows the output waveform while the test is running. The same set is used for cable, motor and generator insulation, where the capacitance of the specimen makes a 50 Hz test impractical.

Single-coupled ultra-low frequency VLF hipot tester structure diagramSeries ultra-low frequency VLF hipot tester structure diagramTwo-stage booster series connection diagramSingle-link connection diagram for tests below 50kVVLF hipot tester test interfaceVLF hipot tester operation screenVLF hipot tester display screenVLF Tan Delta testing diagram

Why tan delta is measured during the withstand test

A withstand test answers one question: did the insulation survive the voltage? Tan delta answers a different one: how lossy was the insulation while it was under stress? Measuring both in the same run means the specimen is energised once, and the loss reading is tied to the same temperature, the same voltage and the same cable length as the withstand result. For cable joints, terminations and aged feeders, the trend across successive tests is usually more useful than any single number.

Series range and load capability

Five peak ratings are listed for this platform. The frequency changes automatically between 0.1 Hz and 0.01 Hz, and the load capability depends on the voltage class and, above 50 kV, on the test voltage itself.

ModelRated voltageLoad capabilityApplication range
XHDP-3030 kV (peak)≤ 10 uF at 0.1-0.01 HzCables and motors up to 10 kV
XHDP-4040 kV (peak)≤ 10 uF at 0.1-0.01 HzCables and motors up to 10 kV
XHDP-5050 kV (peak)≤ 6 uF at 0.1-0.01 HzCables and motors up to 15 kV
XHDP-6060 kV (peak)≤ 5 uF at 0.1-0.01 HzCables and motors up to 25 kV
XHDP-8080 kV (peak)≤ 6 uF up to 50 kV, ≤ 4 uF above 50 kVCables and motors up to 35 kV

Single booster or two in series

Ratings up to 60 kV use a single booster; ratings above 60 kV use two boosters in series. The series connection is what brings 80 kV into a set that one person can move in two trips, and each booster can also be used on its own for lower voltage work.

Measurement and protection

High side samplingVoltage and current are taken directly from the high voltage side, so the reading is the value at the specimen rather than a scaled value from the low side.
Closed-loop feedbackNegative feedback on both sides removes the capacitance-rise effect, so the set voltage stays the set voltage as cable length increases.
Protection below 20 msOver-voltage, over-current and low-resistance fault protection trip the output in less than 20 ms, before a breakdown can damage the booster.
150 kV output leadThe high voltage lead is rated 150 kV, which covers the full 80 kV range with margin and removes the need for a separate lead.

Technical specifications

ParameterValue
Output voltage30 kV to 80 kV peak, model dependent
Output frequencyAutomatic conversion, 0.1 Hz to 0.01 Hz
AC voltage resolution0.1 kV
Voltage accuracy3 %
AC current resolution0.1 mA
Current accuracy3 %
Peak voltage error≤ 3 %
Waveform distortion≤ 3 %
Supply220 V +/- 5 %, 50 Hz (110 V, 60 Hz version available); a micro generator needs a frequency-conversion supply
Service conditionsIndoor or outdoor, -10 C to +40 C, humidity ≤ 85 % RH

Where the set is used

  • After-laying and after-jointing withstand tests on 10 kV to 35 kV XLPE cable.
  • Motor and generator insulation tests during a planned shutdown.
  • Tan delta trending on joints, terminations and aged cable sections.
  • Commissioning work where one portable set has to cover several voltage classes.
Tan delta readings depend on the specimen, its temperature and the test voltage. The set measures and records the value; the pass criteria come from the standard or the utility procedure that applies to the cable being tested.

Frequently asked questions

Does this set measure tan delta as well as withstand voltage?

Yes. Tan delta is measured during the 0.1 Hz withstand test, so the loss reading and the withstand result come from the same energised run at the same temperature.

How much capacitance can the 80 kV model carry?

Up to 6 uF at test voltages up to 50 kV, and up to 4 uF above 50 kV. The 50 kV model carries up to 6 uF and the 30 kV and 40 kV models up to 10 uF.

Is it one booster or two?

Ratings up to 60 kV use one booster. The 80 kV rating uses two boosters in series, and each booster can be used separately for lower voltage work.

Can it run from a small generator?

The set is designed for 220 V +/- 5 %, 50 Hz. A micro generator needs a frequency-conversion supply; a generator with a fluctuating output is not suitable for the automatic boost sequence.

Configuration check

Send the cable classes, the capacitance per phase and whether you need tan delta trending, and we will confirm the rating and the booster configuration.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.