A portable 0.1 Hz AC withstand set for cable and motor insulation, with tan delta measurement taken during the same test and a controller shared across the 30-80 kV range.
The XHDP series is a portable AC withstand voltage set built around digital frequency conversion and microcomputer control. Boost, step-down, measurement and protection run automatically, and the colour touchscreen shows the output waveform while the test is running. The same set is used for cable, motor and generator insulation, where the capacitance of the specimen makes a 50 Hz test impractical.
A withstand test answers one question: did the insulation survive the voltage? Tan delta answers a different one: how lossy was the insulation while it was under stress? Measuring both in the same run means the specimen is energised once, and the loss reading is tied to the same temperature, the same voltage and the same cable length as the withstand result. For cable joints, terminations and aged feeders, the trend across successive tests is usually more useful than any single number.
Five peak ratings are listed for this platform. The frequency changes automatically between 0.1 Hz and 0.01 Hz, and the load capability depends on the voltage class and, above 50 kV, on the test voltage itself.
| Model | Rated voltage | Load capability | Application range |
|---|---|---|---|
| XHDP-30 | 30 kV (peak) | ≤ 10 uF at 0.1-0.01 Hz | Cables and motors up to 10 kV |
| XHDP-40 | 40 kV (peak) | ≤ 10 uF at 0.1-0.01 Hz | Cables and motors up to 10 kV |
| XHDP-50 | 50 kV (peak) | ≤ 6 uF at 0.1-0.01 Hz | Cables and motors up to 15 kV |
| XHDP-60 | 60 kV (peak) | ≤ 5 uF at 0.1-0.01 Hz | Cables and motors up to 25 kV |
| XHDP-80 | 80 kV (peak) | ≤ 6 uF up to 50 kV, ≤ 4 uF above 50 kV | Cables and motors up to 35 kV |
Ratings up to 60 kV use a single booster; ratings above 60 kV use two boosters in series. The series connection is what brings 80 kV into a set that one person can move in two trips, and each booster can also be used on its own for lower voltage work.
| Parameter | Value |
|---|---|
| Output voltage | 30 kV to 80 kV peak, model dependent |
| Output frequency | Automatic conversion, 0.1 Hz to 0.01 Hz |
| AC voltage resolution | 0.1 kV |
| Voltage accuracy | 3 % |
| AC current resolution | 0.1 mA |
| Current accuracy | 3 % |
| Peak voltage error | ≤ 3 % |
| Waveform distortion | ≤ 3 % |
| Supply | 220 V +/- 5 %, 50 Hz (110 V, 60 Hz version available); a micro generator needs a frequency-conversion supply |
| Service conditions | Indoor or outdoor, -10 C to +40 C, humidity ≤ 85 % RH |
Yes. Tan delta is measured during the 0.1 Hz withstand test, so the loss reading and the withstand result come from the same energised run at the same temperature.
Up to 6 uF at test voltages up to 50 kV, and up to 4 uF above 50 kV. The 50 kV model carries up to 6 uF and the 30 kV and 40 kV models up to 10 uF.
Ratings up to 60 kV use one booster. The 80 kV rating uses two boosters in series, and each booster can be used separately for lower voltage work.
The set is designed for 220 V +/- 5 %, 50 Hz. A micro generator needs a frequency-conversion supply; a generator with a fluctuating output is not suitable for the automatic boost sequence.
Send the cable classes, the capacitance per phase and whether you need tan delta trending, and we will confirm the rating and the booster configuration.