An automatic-sweep VLF set that combines AC withstand, DC withstand, tan delta, partial discharge and insulation resistance in one instrument, for cable and motor insulation diagnostics from 10 kV to 35 kV.
The XHDPJ series is the diagnostic version of the XHDP platform. It keeps the 0.1 Hz AC withstand function and adds DC withstand, tan delta, partial discharge and insulation resistance measurement, so a single energised test can produce the withstand result and the diagnostic values that explain it. The frequency sweeps automatically between 0.1 Hz and 0.01 Hz, and the controller is the same 4 kg unit across the range.
| Model | Rated voltage | Load capability | Structure and weight | Application range |
|---|---|---|---|---|
| XHDPJ-30 | 30 kV (peak) | ≤ 10 uF at 0.1-0.01 Hz | Controller 4 kg / booster 25 kg | Cables and motors up to 10 kV |
| XHDPJ-50 | 50 kV (peak) | ≤ 10 uF at 0.1-0.01 Hz | Controller 4 kg / booster 25 kg | Cables and motors up to 15 kV |
| XHDPJ-60 | 60 kV (peak) | ≤ 5 uF at 0.1-0.01 Hz | Controller 4 kg / booster 25 kg | Cables and motors up to 25 kV |
| XHDPJ-80/90 | 80/90 kV (peak) | ≤ 10 uF up to 50 kV, ≤ 4 uF above 50 kV | Controller 4 kg; first stage 25 kg, second stage 45 kg | Cables and motors up to 35 kV |
A fixed 0.1 Hz output is enough for a short feeder, but a long cable can exceed the load limit at that frequency. Instead of refusing the specimen, the XHDPJ lowers the output frequency between 0.1 Hz and 0.01 Hz until the load fits the set. The applied voltage stays the same; only the rate at which it is delivered changes. That is what allows one 4 kg controller to cover specimens from a short motor winding to a long distribution feeder.
DC withstand, tan delta, partial discharge and insulation resistance measurement, in addition to the 0.1 Hz AC withstand function. The AC hardware and the 4 kg controller are shared with the standard platform.
The frequency changes automatically between 0.1 Hz and 0.01 Hz. A lower frequency is selected when the specimen capacitance is too high for the 0.1 Hz load limit.
Up to 10 uF at test voltages up to 50 kV, and up to 4 uF above 50 kV. The 30 kV and 50 kV models carry up to 10 uF and the 60 kV model up to 5 uF.
Yes. The range covers cable and motor insulation from the 10 kV class up to the 35 kV class, with the model selected by the highest test voltage in the list.
Send the cable classes, the capacitance per phase and the diagnostic values you need to record, and we will confirm the model and the booster arrangement.