logo
Home > Products >
AC DC Hipot Tester
>
Cable Hipot Tester XHDP 0.1Hz Very Low Frequency 30kV 50kV 80kV Voltage Generator

Cable Hipot Tester XHDP 0.1Hz Very Low Frequency 30kV 50kV 80kV Voltage Generator

Product Details:
Place of Origin: China
Brand Name: XZH Test
Certification: ISO/CE
Model Number: XHDP-30/50/80
Detail Information
Place of Origin:
China
Brand Name:
XZH Test
Certification:
ISO/CE
Model Number:
XHDP-30/50/80
Model NO.:
XHDP-30/50/80
Customized:
Customized
Color:
Black
Transport Package:
Exported Wooden Case
Trademark:
XZH TEST
Origin:
China
Supply Ability:
2000PCS/Year
Customization:
Available
After-sales Service:
Warranty Certificate
Warranty:
12 Months
Highlight:

High Light

Highlight:

VLF hipot tester 0.1Hz

,

high voltage generator cable tester

,

AC DC hipot tester with warranty

Trading Information
Minimum Order Quantity:
1unit
Packaging Details:
wooden box
Delivery Time:
5-8work days
Payment Terms:
T/T
Supply Ability:
2000unit/year
Product Description
XHDP 30 / 50 / 80 kV · CABLE TESTING
Cable Hipot Tester XHDP 0.1Hz Very Low Frequency 30kV 50kV 80kV Voltage Generator
0.1 Hz cable hipot
10 / 15 / 35 kV cable classes
Light enough for field work

This XHDP configuration is aimed at cable work: a 0.1 Hz very low frequency AC hipot that replaces the power frequency test on XLPE cable, where the insulation capacitance would otherwise call for a resonant set of several hundred kilograms. The three ratings offered - 30 kV, 50 kV and 80 kV peak - map onto 10 kV, 15 kV and 35 kV cable classes.

Choosing 0.1 Hz instead of 50 Hz cuts the capacity the source must supply to about one five-hundredth, so a 4 kg controller and a booster of 20 to 50 kg do the job. The set runs at 0.1 Hz, 0.05 Hz and 0.02 Hz with 1.1 µF, 2.2 µF and 5.5 µF load capability, which covers a single-phase cable length typical of distribution feeders.

Product View
Xzh Test AC Cable Hipot Tester Vlf 0.1Hz Very Low Frequency High Voltage Generator
Xzh Test AC Cable Hipot Tester Vlf 0.1Hz Very Low Frequency High Voltage Generator
Xzh Test AC Cable Hipot Tester Vlf 0.1Hz Very Low Frequency High Voltage Generator
Who This Set Is For

This is the set for organisations whose test object is almost always a length of cable.

Cable installation contractors carrying out the after-laying AC test before a feeder is energised.
Distribution network operators testing 10 kV and 15 kV feeders after jointing, termination work or a fault repair.
Industrial sites with their own 35 kV cable network that need the test done in house without a resonant trailer.
One phase is tested at a time, so the capacitance to check against the load limit is that of a single phase to earth, not the whole three-phase circuit.
Key Features
Three cable-oriented ratings: 30 kV for 10 kV class, 50 kV for 15 kV class and 80 kV for 35 kV class cable.
0.1 Hz output that replaces the power frequency AC test, at roughly one five-hundredth of the source capacity.
Load capability of 1.1 µF at 0.1 Hz, 2.2 µF at 0.05 Hz and 5.5 µF at 0.02 Hz on each rating.
Controller of 4 kg with boosters from 20 kg to 50 kg, so one person can move the set along a cable route.
Automatic boost, buck, measurement and protection with a 3 % accuracy and a 10 ms protection time.
Closed-loop feedback that keeps the output free of capacitance rise as cable length increases.
Touch screen operation with automatic storage and printing of each cable test record.
Technical Specifications
Model range
ModelRated voltage0.1 Hz0.05 Hz0.02 HzSupply fuseController / booster
XHDP-3030 kV (peak)≤ 1.1 µF≤ 2.2 µF≤ 5.5 µF10 A4 kg / 20 kg
XHDP-5050 kV (peak)≤ 1.1 µF≤ 2.2 µF≤ 5.5 µF15 A4 kg / 40 kg
XHDP-8080 kV (peak)≤ 1.1 µF≤ 2.2 µF≤ 5.5 µF15 A4 kg / 50 kg
Common specifications
ParameterValue
Output frequencies0.1 Hz, 0.05 Hz and 0.02 Hz, selectable
Measurement accuracy3 %
Peak voltage error≤ 3 %
Waveform distortion≤ 5 %
Protection operating time≤ 10 ms
Supply220 V ± 5 %, 50 Hz ± 5 Hz; a portable generator needs more than 3 kW with a stable 220 V / 50 Hz output
Service conditionsIndoor or outdoor, -10 °C to +40 °C, humidity ≤ 85 % RH
Frequently Asked Questions
Q1.Which rating matches a 35 kV cable?
The 80 kV peak unit. 30 kV covers 10 kV class cable, 50 kV covers 15 kV class, and 80 kV is the rating for 35 kV class cable, where it carries 1.1 µF at 0.1 Hz.
Q2.How long a cable can be tested?
It depends on the capacitance per kilometre of the cable. The set carries 1.1 µF at 0.1 Hz, 2.2 µF at 0.05 Hz and 5.5 µF at 0.02 Hz, so a long run is tested at the lower frequency once its single-phase capacitance is known.
Q3.Is the whole three-phase circuit tested at once?
No. Cables are tested phase by phase with the other phases earthed, so the capacitance used for the load check is a single phase to earth.
Q4.Can the set be carried along a cable route?
Yes. The controller weighs 4 kg and the booster 20 kg on the 30 kV unit, 40 kg on the 50 kV unit and 50 kg on the 80 kV unit, which is why the 0.1 Hz method is used for field cable testing.
Q5.What supply is needed at the test point?
220 V ± 5 %, 50 Hz ± 5 Hz, or a portable generator above 3 kW with a stable output. The supply fuse is 10 A on the 30 kV unit and 15 A on the 50 kV and 80 kV units.
Configuration check
Send us the cable type, the length per phase and the voltage class, and we will calculate the capacitance and confirm which rating keeps you inside the load limit at 0.1 Hz.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.