Power Cable DC Hipot Tester XHZG Series 120kV 2mA Withstand Test Equipment

Power Cable DC Hipot Tester XHZG Series 120kV 2mA Withstand Test Equipment

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHZG series
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHZG series
Rated Output Voltage:
30kV/50kV/80kV
Accuracy:
3%
Output Frequency:
0.1Hz, 0.05Hz, 0.02Hz
Load Capacity:
Max 1.1μF@0.1Hz, Max 2.2μF@0.05Hz, Max 5.5μF@0.02Hz
Positive & Negative Peak Voltage Error:
≤3%
Voltage Waveform Distortion:
≤5%
Highlight:

High Light

Highlight:

120kV Cable Hipot Tester

,

DC Withstand Test

,

XHZG Cable Test Set

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
8-10 days
Payment Terms:
T/T
Supply Ability:
2000units/year
Product Description
120 kV Cable Testing

Power Cable DC Hipot Tester XHZG Series 120kV 2mA Withstand Test Equipment

A 120 kV, 2 mA DC hipot tester for power cable withstand testing, covering 35 kV and 66 kV cable classes and the leakage reading that goes with the withstand result.

120 kV
2 mA
240 W
13 kg + 3.2 kg

Long cable, 120 kV

Cable insulation tests are limited by both voltage and charging current. 120 kV covers the 35 kV and 66 kV classes, and 2 mA is enough for the cable lengths usually tested from a single termination. For very long sections, calculate the charging current before the test and compare it with the output rating.

Test sequence

The usual sequence is a voltage step to the specified test level, a hold for the specified time, then a controlled reduction and discharge. The leakage current is recorded at each step. A rise in current without a rise in voltage is the signal to stop and investigate.

Reading and recording

Voltage and current are sampled on the high voltage side and shown together, so the leakage value corresponds to the voltage actually applied. The reading, the cable temperature and the ambient conditions should go into the record, because a cable tested cold and one tested after loading are not directly comparable.

Safety around the termination

The test area is barriered, the far end is guarded, and the cable is earthed and discharged before anyone touches it. The set discharges the specimen when the test stops, but the manual earth-and-discharge step is still required.

Configurations

Configuration 120 kV / 2 mAOutput voltageOutput currentOutput powerCharging currentControl boxMultiplier
120 kV / 2 mA12022403133.2

Measurement and operating data

ParameterValue
Voltage measurement error<= 1.0 % (full scale) +/- 1 digit
Current measurement error<= 1.0 % (full scale) +/- 1 digit
Ripple factor<= 0.5 %
0.75UDC-1mA buttonPrecision <= 1.0 %
Working mode30 min at rated load; 10 min at 1.1 times rated voltage

Frequently asked questions

What cable classes can it test?

35 kV and 66 kV cable classes, with the test voltage set by the standard applied on site. Longer sections should be checked against the 2 mA charging current.

How long can the set run?

30 minutes at rated load, with a short-term rating of 10 minutes at 1.1 times rated voltage.

Does it measure leakage current?

Yes. Voltage and current are displayed together, and the leakage at each step is recorded.

Cable test check

Send the cable class, length and capacitance per phase, and we will confirm whether the 120 kV / 2 mA configuration covers the charging current and the test voltage.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.