AC DC Hipot Tester
>
Transformer DC Withstand Tester XHZG Series 120kV 2mA Hipot Equipment Set

Transformer DC Withstand Tester XHZG Series 120kV 2mA Hipot Equipment Set

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHZG series
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHZG series
Rated Output:
30kV/50kV/80kV
Measurement Precision:
3%
Optional Output Frequencies:
0.1Hz, 0.05Hz, 0.02Hz
Maximum Load:
1.1μF (0.1Hz), 2.2μF (0.05Hz), 5.5μF (0.02Hz)
Peak Voltage Deviation (Positive/Negative):
≤3%
Waveform Distortion Rate:
≤5%
Highlight:

High Light

Highlight:

Transformer DC Withstand Tester

,

120kV Hipot Equipment

,

XHZG Transformer Test

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
8-10 days
Payment Terms:
T/T
Supply Ability:
2000units/year
Product Description
Transformer and Breaker

Transformer DC Withstand Tester XHZG Series 120kV 2mA Hipot Equipment Set

A 120 kV, 2 mA DC withstand tester for transformer and breaker insulation, used in planned outages where the winding or the interrupter insulation has to be proved before the equipment is returned to service.

120 kV
2 mA
Transformer and breaker
0.75UDC-1mA

Transformer insulation

A transformer winding is tested at DC for insulation resistance and withstand. The 120 kV class covers the insulation levels of many distribution and sub-transmission transformers, and 2 mA is sufficient for the winding capacitance involved. The oil and winding temperature should be recorded, because insulation resistance changes with temperature.

Breaker and switchgear

Vacuum and SF6 interrupters, bushings and support insulation are checked at DC during maintenance. The test is short and the current is small, which is why a 2 mA set is adequate and a larger source adds nothing to the result.

Arresters on the same visit

The 0.75UDC-1mA function covers arresters on the same site, so a transformer or breaker test and an arrester check can be planned for the same outage. The transformer, breaker and arrester results are recorded separately, each with its own test voltage and current.

Portable build

The control box is 13 kg and the multiplier 3.2 kg at 120 kV / 2 mA. The two pieces are carried separately, which keeps the set usable where a trolley cannot reach.

Configurations

Configuration 120 kV / 2 mAOutput voltageOutput currentOutput powerCharging currentControl boxMultiplier
120 kV / 2 mA12022403133.2

Measurement and operating data

ParameterValue
Voltage measurement error<= 1.0 % (full scale) +/- 1 digit
Current measurement error<= 1.0 % (full scale) +/- 1 digit
Ripple factor<= 0.5 %
0.75UDC-1mA buttonPrecision <= 1.0 %
Working mode30 min at rated load; 10 min at 1.1 times rated voltage

Frequently asked questions

Is 2 mA enough for a transformer?

Yes for the winding capacitance of the transformers covered by 120 kV. The charging current should still be checked for very large units.

Can it test breakers?

Yes. Breaker insulation, bushings and support insulation within 120 kV are tested with the same DC output.

Does it test arresters too?

Yes. The 0.75UDC-1mA reference function is included.

Outage test list

Send the transformer and breaker ratings on the outage list, and we will confirm the voltage and current class that covers them.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.