Cable Insulation DC Hipot Tester XHZG Series 60kV 5mA Motor Test Equipment

Cable Insulation DC Hipot Tester XHZG Series 60kV 5mA Motor Test Equipment

Product Details:
Place of Origin: Xi'an, Shaanxi, China
Brand Name: XZH TEST
Certification: ISO,CE
Model Number: XHZG series
Detail Information
Place of Origin:
Xi'an, Shaanxi, China
Brand Name:
XZH TEST
Certification:
ISO,CE
Model Number:
XHZG series
Structural Characteristics:
Compatible With Capacitive Load, Unlimited Capacitance Of Tested Objects
Altitude:
Below 1500m
Relative Humidity:
≤85% At 25℃ (no Condensation)
Temperature:
-10℃ ~ +40℃
Working Mode:
Intermittent Operation; 30 Mins Under Rated Load, 10 Mins Under 1.1 Times Rated Voltage
Parameter Value Output Voltage (kV) 60 Output Current (mA) 5 Output Power (W) 120 Voltage Measuremen:
≤0.2%
Highlight:

High Light

Highlight:

60kV 5mA DC Hipot

,

Cable Insulation Tester

,

XHZG Motor Test Set

Trading Information
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
wooden packaging
Delivery Time:
8-10 days
Payment Terms:
T/T
Supply Ability:
2000units/year
Product Description
60 kV / 5 mA

Cable Insulation DC Hipot Tester XHZG Series 60kV 5mA Motor Test Equipment

A 60 kV, 5 mA DC hipot tester for cable and motor insulation, where the higher current class shortens the charging time on specimens with more capacitance.

60 kV
5 mA
300 W
0.75UDC-1mA

Why 5 mA

At a given voltage, a specimen with more capacitance takes longer to charge and draws more current during the test. The 5 mA class charges that specimen in a practical time where a 2 mA set would sit waiting. For cable sections and motor windings the difference is often the reason the test fits into the outage window.

Cable capacitance and charging current

A cable is a capacitor. Its capacitance rises with length, and the charging current rises with capacitance and voltage. Before the test, compare the calculated charging current with the 5 mA output so that the set is not asked to hold a current it cannot supply.

Motor insulation

Motor and generator windings are tested at DC for insulation resistance and withstand. The 5 mA output covers most low and medium voltage machines inside 60 kV. The winding temperature should be recorded with the result, because insulation resistance moves with temperature.

Reference point for arresters

The 0.75UDC-1mA button is included, so an arrester on the same site can be tested with the same set. The precision for this function follows the 60/5 configuration document.

Configurations

Configuration 60 kV / 5 mAOutput voltageOutput currentOutput powerCharging currentControl boxMultiplier
60 kV / 5 mA6053007.511.62.3

Measurement and operating data

ParameterValue
Voltage measurement error+/- 1 % (full scale) +/- 1 digit
Current measurement error+/- 1 % (full scale) +/- 1 digit
Ripple factor<= 0.5 %
0.75UDC-1mA buttonPrecision <= 0.5 %
Working mode30 min at rated load; 10 min at 1.1 times rated voltage

Frequently asked questions

When is 5 mA better than 2 mA?

When the specimen capacitance is large enough that charging at 2 mA would take too long, typically longer cable sections and larger motor windings.

Can it test a 10 kV motor?

Yes. A 10 kV motor insulation test sits well inside the 60 kV range; the test voltage comes from the applicable standard.

Does it include the arrester function?

Yes. The 0.75UDC-1mA reference button is provided for zinc oxide arrester testing.

Cable and motor check

Send the cable length and capacitance per phase, or the motor rating, and we will confirm whether 5 mA covers the charging current.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

N
Nikolaos Papadopoulos
Greece Jul 7.2026
Η συσκευή XHDP‑80M δοκιμής υπερβολικά χαμηλής συχνότητας έχει εξαιρετική απόδοση για την ομάδα διανομής μας. Πραγματοποιήσαμε δοκιμές αντοχής σε υπόγεια καλώδια 20kV στον υποσταθμό Κερατέας κοντά στην Αθήνα. Η λειτουργία με οθόνη αφής είναι εύκολη, η προστασία ενεργοποιείται γρήγορα και οι μετρήσεις παραμένουν ακριβείς ακόμα στη μεσογειακή ζέστη. Ανθεκτική κατασκευή για εργασίες πεδίου, μειώνει σημαντικά τον χρόνο προετοιμασίας των δοκιμών. Συνιστάται ανεπιφύλακτα για τα συνεργεία ηλεκτρικής ενέργειας στην Ελλάδα.