Output Voltage:
0~80kV (Optional)
Booster Capacity:
1.5kVA
Boost Speed:
2.0/2.5/3.0/3.5 KV/s (4 Levels), Error 0.2kV/s
Voltage Accuracy:
±(2% Reading + 2 Digits)
Power Distortion Rate:
<1%
Electrode Gap Standard:
2.5mm
Test Positions:
3 Oil Cups (Simultaneous Testing)
Number Of Tests:
6 Times (1-6 Times Optional)
Standing Time:
5 Minutes (1-9 Minutes Adjustable)
Testing Standards:
GB1986, GB2002, Custom
Oil Cup Material:
Special Glass, One-Time Casting (Leak-Proof)
Safety Features:
Over-Current, Over-Voltage, Short-Circuit Protection, Grounding Alarm
Display:
LCD Screen With Temperature, Humidity & Clock Display
Power Supply:
AC 220V±10%, 50Hz±10%
Power Consumption:
<200W
Operating Temperature:
0℃~40℃
Operating Humidity:
≤85%
Dimensions:
670 × 420 × 410mm
Weight:
42kg
Highlight:

High Light

Highlight:

Three-Cup Insulation Oil Tester

,

Automatic Dielectric Strength Tester

,

Transformer Laboratory Testing Equipment

Trading Information
Minimum Order Quantity:
1 Unit
Price:
Negotiable
Packaging Details:
Wooden case packaging with shock-proof foam, export-grade corrugated carton
Delivery Time:
5-10 Working Days
Payment Terms:
T/T
Supply Ability:
300 Units per Year
Product Description
XHYY102S Three-Cup Insulation Oil Dielectric Strength Tester High-Throughput Simultaneous 3-Sample Breakdown Voltage Analysis — GB & IEC Compliant
Product Overview

The XHYY102S Three-Cup Insulation Oil Dielectric Strength Tester is a high-capacity, fully automatic industrial instrument purpose-built for electrical power systems, railway networks, and large petrochemical facilities that manage extensive fleets of oil-filled electrical equipment. Independently developed in accordance with GB/T507-2002, DL429.9-91, and DL/T846.7-2004 standards, the XHYY102S employs a single-chip microcontroller core to achieve full test automation with exceptional measurement precision, dramatically improving laboratory throughput while reducing operator workload.

Engineered as the high-throughput variant in the XHYY102 series, the XHYY102S features three independent oil cup positions for simultaneous testing of three samples in a single run. Each oil cup is manufactured from special glass using one-time casting technology to eliminate leakage and interference phenomena. The instrument incorporates a grounding alarm system for enhanced operator safety, integrated temperature/humidity/clock display, and a wide-range watchdog circuit for crash-free continuous operation. A dedicated boost rate switch provides instant selection between four standardized speed settings (2.0/2.5/3.0/3.5 kV/s).

XHYY102S

Key Features
  • Three-Cup Simultaneous Testing: Three independent oil cup positions enable parallel dielectric strength measurement of three samples in a single automated run, tripling laboratory throughput
  • Single-Chip Microcomputer Control: Large-capacity microcontroller with wide-range watchdog circuit ensures stable, reliable, crash-free operation for continuous heavy-duty use
  • Grounding Alarm System: Dedicated safety feature monitors ground connection integrity and alerts operators to potential hazards before high-voltage testing begins
  • Dedicated Boost Rate Switch: Physical selector for instant switching between 2.0, 2.5, 3.0, and 3.5 kV/s rates with 0.2kV/s accuracy, eliminating menu navigation during protocol changes
  • Environmental Monitoring: Integrated temperature and humidity sensors with real-time digital display for comprehensive test condition documentation
  • High-Voltage Direct Sampling: Unique high-voltage terminal design feeds test values directly to the A/D converter, bypassing analog circuit errors for superior accuracy
  • Multi-Standard Compliance: Pre-loaded with GB1986, GB2002, and user-defined custom protocols to accommodate diverse testing requirements
  • Comprehensive Protection Suite: Over-current, over-voltage, and short-circuit protection with strong electromagnetic compatibility for reliable substation and factory floor deployment
  • Built-in Thermal Printer: Automatic printing of individual and averaged multi-test results for immediate documentation
  • Rugged Construction: Heavy-duty 42kg chassis (670x420x410mm) with special glass one-piece cast oil cups for leak-proof, long-service-life operation
Technical Specifications
High Voltage Output
Output Voltage 0~80kV (Optional)
Booster Capacity 1.5kVA
Boost Speed 2.0 / 2.5 / 3.0 / 3.5 kV/s (4 Levels), Error 0.2kV/s
Voltage Accuracy ±(2% Reading + 2 Digits)
Power Distortion Rate <1%
Testing Configuration
Test Positions 3 Oil Cups (Simultaneous Testing)
Electrode Gap Standard 2.5mm
Number of Tests 6 Times (1-6 Times Optional)
Standing Time 5 Minutes (1-9 Minutes Adjustable)
Testing Standards GB1986, GB2002, Custom (User-Defined)
Oil Cup Material Special Glass, One-Time Casting (Leak-Proof)
Interface & Safety
Display LCD Screen with Temp/Humidity/Clock Display
Safety Features Grounding Alarm, Over-Current, Over-Voltage, Short-Circuit Protection
Data Output Built-in Thermal Printer
Controls Function Keys + Physical Boost Rate Selector Switch
Operating Specifications
Power Supply AC 220V±10%, 50Hz±10%
Power Consumption <200W
Operating Temperature 0℃~40℃
Operating Humidity ≤85%
Physical Specifications
Dimensions 670 × 420 × 410mm
Weight 42kg
Frequently Asked Questions
Q1: What is the primary advantage of the three-cup design over single-cup testers?
The XHYY102S three-cup design enables simultaneous dielectric strength testing of three independent oil samples in a single automated run. For laboratories processing large volumes of transformer oil samples—such as utility maintenance depots, transformer manufacturing quality control, and third-party testing service providers—this triples daily throughput compared to single-cup instruments. Each cup operates independently with its own electrode set, and results are printed individually with automatic averaging, eliminating cross-contamination concerns between samples.
Q2: How does the grounding alarm system enhance operator safety?
The XHYY102S features a dedicated grounding alarm that continuously monitors the integrity of the earth connection before and during high-voltage testing. If the ground connection is compromised—due to loose cabling, corrosion, or improper setup—the instrument immediately alerts the operator via a visual indicator and prevents high-voltage output from being initiated. This is critical for 80kV testing environments where proper grounding is essential for both personnel safety and measurement accuracy, particularly in field substation deployments.
Q3: What is the difference between the XHYY102S and the XHYY102/XHYY102M models?
The XHYY102S is the high-throughput, heavy-duty variant with three simultaneous oil cup positions, a dedicated physical boost rate selector switch (2.0/2.5/3.0/3.5 kV/s), grounding alarm, and a rugged 42kg chassis. The XHYY102 is the standard single-cup model with ten-level boost speed control. The XHYY102M is the touch screen upgrade with RS232 connectivity and bilingual support. The XHYY102S is optimized for laboratories and facilities requiring maximum sample throughput with minimal operator intervention, while the XHYY102/M models target precision single-sample analysis with advanced data connectivity.
Q4: What maintenance is required for the three oil cup assemblies?
Each oil cup is manufactured from special glass via one-time casting technology, providing inherent leak-proof performance and chemical resistance. Routine maintenance includes cleaning cups with appropriate solvents (methanol), inspecting electrode gaps for the 2.5mm standard spacing, and periodically applying a thin layer of vacuum grease to ground joints for smooth rotation. The dedicated boost rate selector switch requires no calibration. Annual verification against reference oil standards is recommended for ISO 17025 accredited laboratories. Replacement oil cups and electrode sets are available as spare parts.
Q5: What are the MOQ, delivery terms, and after-sales support for the XHYY102S?
The minimum order quantity is 1 unit, with payment via T/T or L/C. Standard delivery is 5-10 working days with secure wooden case packaging for the 42kg instrument. Annual supply capacity reaches 300 units. Each XHYY102S includes a 12-month comprehensive warranty covering manufacturing defects, with lifetime technical support and repair services. Non-standard voltage ranges and OEM branding are available upon request. For volume pricing for multi-unit laboratory deployments, extended warranty packages, or technical consultation, please contact our sales team directly.